Electrical Connection - Blodgett 1415 Installation, Operation And Maintenance Manual

Blodgett electric compact deck oven
Table of Contents

Advertisement

Installation

Electrical Connection

Ovens are supplied for operation on 208 volt or
220-240 volt installation. The thermostat, indicator
Wiring Label
light and related switches are interconnected
through one power source supplied to the oven.
Before making any connection to this oven, check
the rating plate attached to the bodyback to as-
sure that the voltage, phase and KW rating are
compatible with the electrical supply. See dia-
gram.
All ovens, when installed, must be connected and
electrically grounded in accordance with local
codes, or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70---Latest
Edition and/or Canadian
Electric Code CSA
C22.1 as applicable.
Wiring diagrams are located on the bodyback.
The supply conduit enters through the rear of the
Rating
Plate
oven and electrical connection is made to the ter-
Wiring
minal block secured to the panel at the back of the
Schematic
control compartment. Electrical connection sizes
for a double 1400 oven are shown in "Electrical
Connection AWG" column of the Electrical Specifi-
Installation Instructions
cations found on page 2 of this manual. Wiring is
"Do not install closer than
sized for 75_C copper wire at 125% of rated input.
2 inches to any side or rear wall"
Reference is from the National Electric Code ANSI/
NFPA 70- Latest Edition.
Figure 1
4

Advertisement

Table of Contents
loading