La taille du climatiseur convient-elle à la
superficie de la pièce à refroidir ?
Voir le guide ci-dessous.
Consignes
Autres conditions :
·
·
·
Remarque :
NORD OU OMBRAGÉE
Tˆƒr…svpvrÃ
Capacité de refroidissement du climatiseur
jÃ…rs…‚vqv…Ã
Btu/heure
rÃƒvrq†Ã
ph……p†Ã
R
150
3,200
3,500
4,400
É
200
3,600
4,000
5,200
250
4,000
4,400
5,900
300
4,300
4,900
6,600
G
350
4,700
5,300
7,400
400
5,100
5,800
8,200
I
450
5,500
6,200
8,900
500
5,800
6,600
9,600
550
6,200
7,100
10,400
O
600
6,600
7,600
11,100
650
6,900
8,000
11,800
N
700
7,300
8,400
12,600
750
7,700
8,900
13,400
800
8,000
9,400
14,100
850
8,300
9,800
14,900
1
900
8,700
10,200
15,600
950
9,100
10,700
16,300
1000
9,400
11,100
17,100
1100
10,100
12,000
18,500
1200
10,900
12,900
20,000
1300
11,600
13,800
21,500
1400
12,300
14,700
23,000
Rochester
Fargo
Eugene
Green Bay
Reno
Sacramento
Columbus
Pueblo
Wichita
Fresno
Charlotte
Flagstaff
Las
Vegas
Atlanta
Phoenix
Birmingham
San Antonio
Tucson
1
2
Région 1
Région 2
Région 3
EST OU SUD
OUEST
Capacité de refroidissement du climatiseur
Capacité de refroidissement du climatiseur
Btu/heure
Btu/heure
5,100
5,400
6,200
6,200
6,500
5,500
5,900
7,000
6,600
7,000
6,000
6,400
7,800
7,100
7,500
6,400
6,900
8,600
7,500
8,000
6,800
7,400
9,400
7,900
8,500
7,200
7,900
10,300
8,300
9,000
7,600
8,400
11,100
8,700
9,500
8,000
8,900
11,900
9,100
10,000
8,400
9,400
12,700
9,500
10,500
8,900
9,900
13,500
10,000
11,000
9,300
10,400
14,300
10,400
11,500
9,700
10,900
15,100
10,800
12,000
10,100
11,400
15,900
11,200
12,500
10,600
11,900
16,700
11,700
13,000
11,000
12,400
17,500
12,100
13,500
11,400
12,900
18,300
12,500
14,000
11,800
13,400
19,100
12,900
14,500
12,300
14,000
19,900
13,400
15,100
13,100
14,900
21,400
14,200
16,000
13,900
15,900
23,000
15,000
17,000
14,700
16,900
24,700
15,800
18,000
15,600
17,900
26,300
16,700
19,100
44
To reduce the risk of electric shock, personal injury, or death, turn the fan control to the off
position and remove the unit plug from the wall outlet before doing any inspection or
Albany
maintenance work.
The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause and
New
Haven
suggested remedies are given for each problem.
If the problem cannot be fixed using the suggested remedies, see WHEN SERVICE IS REQUIRED section.
PROBLEM
UNIT WILL NOT RUN
LITTLE OR NO COOLING
3
NOISY UNIT
MOUNTING SUPPORT
NOT INSTALLED
FROST ON INDOOR COIL
ODORS IN COOLING
7,300
8,100
8,900
9,800
10,600
11,400
12,200
13,000
13,800
14,600
15,400
16,200
17,000
17,800
18,600
19,400
20,200
21,000
22,600
24,200
25,800
27,400

Before Calling For Service

WARNING
POSSIBLE CAUSE
No power to the unit.
Obstructed indoor or outdoor air flow.
Dirty air filters.
Unit undersized for application.
Temperature Control not properly set.
Loose front of mounting assembly.
Weak building construction.
Water hitting the fan blade.
Unit oversized for application.
(Compressor cycles on and off frequently.)
Storm window frame has been installed into window.
Dirty air filter.
Normal for low outdoor temperatures.
Oversized unit.
Mold, mildew, or algae formation on wet surfaces.
17
SUGGESTED REMEDY
Set Fan Control to position other than OFF.
Make sure plug is firmly held in outlet.
Check for blown fuses or tripped circuit breakers.
Call for service.
Remove obstruction from indoor grille or outdoor louvers.
Clean the air filter. See Section V for details.
Check with dealer to determine proper capacity unit for your
application.
For cooling turn Temperature Control to higher number.
Call for service.
Tighten any loose parts.
Provide additional support for the unit.
Normal in high humidity. Stop noise by removing drain plug or
adding a condensate drain.
Check with dealer to determine proper capacity unit for
application.
Some models require the storm window frame to be removed
before installation.
Clean the air filter. See Section V for details.
Turning the Temperature Control to a lower number will reduce
occurrence and duration of frosting condition.
Check with dealer to determine proper capacity unit for
application.
To reduce growth use algacide tablet in the unit base pan or
remove drain plug or add a condensate drain. Have your unit
thoroughly cleaned. See Section V.