Amana AAC051SRA Owner's Manual
Hide thumbs Also See for AAC051SRA:

Advertisement

Garantie
PREMIÈRE ANNÉE
DEUXIÈME À CINQUIÈME ANNÉE
LIMITES DE LA GARANTIE :
LIMITES DE GARANTIE :
Part No. 12592301
Printed in U.S.A
CLIMATISEUR D’AIR DE PIÈCE
GARANTIE COMPLÈTE D’UN AN
GARANTIE COMPLÈTE DE CINQ ANS
SUR LES COMPOSANTES DU SYSTÈME SCELLÉ
RESPONSABILITÉS DU PROPRIÉTAIRE :
EN AUCUN CAS AMANA NE PEUT ÊTRE
TENU RESPONSABLE DES DOMMAGES
INDIRECTS OU ACCESSOIRES*
February 2001
©2001Amana Appliances
Amana, Iowa 52204

Room Air Conditioner

Keep manual for future reference. Be sure manual stays with air conditioner.
I. Description ...................................................... 1
II. Unpacking ....................................................... 2
III. Electrical Requirements ................................. 2
IV. Installation ....................................................... 3
V. Normal Care and Maintenance .................... 14
VI. General Operating Instructions ................... 15
VII. Controls .......................................................... 15
Before Calling For Service .................................. 16
When Service is Required .................................. 19
Any Questions? ..................................................... 19
Español .................................................................. 21
Français ................................................................. 41
I. Description
This room air conditioner cools, dehumidifies and filters the
air inside your home.
Sections I through VI of this manual provide general operating
instructions, installation instructions, and maintenance in-
structions for your room air conditioner. These general
instructions apply to all models. Section VII provides control
operation information for each model. After reading Sections
I through VI, turn to Section VII and find the control layout that
matches your specific room air conditioner model. Read the
information on this page carefully.
Owner’s
Manual
Contents
Important:
It is important, both for your personal
safety and to avoid possible damage to your appliance
or your home, that you observe the safety instructions
that are given following this symbol.
!
RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AAC051SRA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Amana AAC051SRA

  • Page 1: Table Of Contents

    II. Unpacking ............2 III. Electrical Requirements ......... 2 IV. Installation ............3 V. Normal Care and Maintenance ....14 EN AUCUN CAS AMANA NE PEUT ÊTRE VI. General Operating Instructions ....15 TENU RESPONSABLE DES DOMMAGES VII. Controls ............15 Before Calling For Service ........
  • Page 2: Unpacking

    Pour de plus amples renseignements concernant cet appareil separately. must be grounded. Do not under any ou tout autre produit Amana, visiter le site Web au Record the model, serial and manufacturing numbers of your circumstances cut or remove the round unit in the space provided below.
  • Page 3: Installation

    IV. INSTALLATION INSTRUCTIONS Installation Requirements Before You Install Consider Description For proper air conditioner operation all vents, indoor and out, must be free of Location obstructions. Carefully survey installation location. Indoor obstructions could include, but are not limited to, furniture, curtains, or plants. Outdoor obstructions could include, but are not limited to, landscaping plants and materials, structural design, or pathways.
  • Page 4 Do you have the right size air conditioner for the room you want to cool? Check the guide below and see. Instructions 1. Measure the room to be cooled in Rochester Fargo Eugene square feet. Albany Green Bay 2. Select the region (1, 2, or 3) that best fits your location from the map.
  • Page 5 Avant d’appeler le service de dépannage NORTH OR EAST OR WEST SHADED SOUTH MISE EN GARDE Pour réduire le risque d’électrocution, de blessures ou de décès, tourner la commande de ventilation à «off» (fermé) et débrancher l’appareil avant de procéder à toute inspection ou travail d’entretien.
  • Page 6: Parts Supplied

    PP RXWHU FDVH DQFKRU VFUHZV EDVHSDQ DQJOH WRS UDLO EDVHSDQ DQJOH DQFKRU JDVNHW PP VFUHZ H[WHUQDO EUDFH MODÈLES : AAC051FRA, AAC051SRA, AAC071FRA PRXQWLQJ VFUHZV FXUWDLQ DWWDFKPHQW H[WHUQDO EUDFHV DQG WRS UDLO VFUHZV DGMXVWDEOH IRRW OHIW DQG ULJKW GUDLQ WXEH PP Models: AA101SRA, AAC121SRA...
  • Page 7 Important Safety Grounding Instructions V. Entretien courant Information For safety, air conditioner must be grounded. All air conditioner power supply MISE EN GARDE cords are equipped with 3-prong grounding plug. Plug on cord must be plugged About Ground Wires Pour réduire le risque d’électrocution, de into appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
  • Page 8 Mobile home window installation travers le mur Add wood strip (at least 1 1/2” wide) If storm window frame does not allow WINDOW FOR AAC051SRA along entire width of window sill. adequate clearance below sill (1/2” AAC081SRA 14 1/2 7 1/2...
  • Page 9 DANS LE BOÎTIER and top of indoor sash. This will EXTÉRIEUR stop air leakage which reduces efficiency. Models: AAC051SRA, AAC081SRA, AAC101SRA, AAC121SRA IMPORTANT : AAC141SRA, AAC182SRA, and AAC202SRA PREPARE UNIT INSTALLATION Unpack unit on floor next to installation location.
  • Page 10 INSTALLER LE BOÎTIER EXTÉRIEUR ASSEMBLE DANS LA FENÊTRE CURTAINS/TOP RAIL Remove paper backing from top rail gasket and adhere to bottom of top rail. Niveau Install top rail with three or four 10-mm Guillotine de screws depending on unit style. Slide la fenêtre left-hand curtain assembly into left end of top and bottom rails.
  • Page 11 INSTALL OUTER FIXATION DES RIDEAUX/ DE LA CRÉMAILLÈRE CASE IN WINDOW SUPÉRIEURE Place outer case in window. Lower sash until it rests behind front flange of top rail. Bottom rail must rest behind window sill. Level Window sash PRÉPARER LA Installation de la contre-fenêtre Installation dans une fenêtre de maison mobile...
  • Page 12 Find someone to help you replace chassis in outer case. Install basepan clip. Replace front panel and grille. Where possible, install Modèles : AAC051SRA, AAC081SRA, AAC101SRA, AAC121SRA two screws in rear of outercase, AAC141SRA, AAC182SRA et AAC202SRA removed in step one.
  • Page 13 Installation dans une fenêtre PRÉPARER LA Installation de la contre-fenêtre Model Dimension de maison mobile FENÊTRE POUR CAUTION L’INSTALLATION AAC051SRA AAC081SRA 14 1/2 7 1/2 Installing air conditioner through a wall requires AAC101SRA 22 1/2 10 5/8 extensive carpentry and/or masonry experience.
  • Page 14: Normal Care And Maintenance

    FRONT GRILLE AND CABINET CLEANING The grille and complete cabinet may be cleaned with warm Models: AAC051FRA, AAC051SRA, AAC071FRA water and mild soap or detergent. Cleaning or polishing METHOD ONE: compounds are not recommended, as they may damage Modèles AAC051FRA et AAC071FRA...
  • Page 15: General Operating Instructions

    Vis d’ancrage de for maximum air circulation and cooling effect. supérieure base 25 mm Vis de fixation MODELS: AAC051FRA, AAC051SRA, AAC071FRA, HIGH FAN – Select this setting for circulating or exhausting d'entretoise externe room air without cooling. Vis de crémaillère Pied réglable...
  • Page 16: Before Calling For Service

    Before Calling For Service NORD OU OMBRAGÉE EST OU SUD OUEST WARNING To reduce the risk of electric shock, personal injury, or death, turn the fan control to the off position and remove the unit plug from the wall outlet before doing any inspection or maintenance work.
  • Page 17 La taille du climatiseur convient-elle à la superficie de la pièce à refroidir ? Voir le guide ci-dessous. Consignes Rochester Fargo Eugene Albany Green Bay Reno Haven Sacramento Columbus Pueblo Wichita Fresno Charlotte Flagstaff Vegas Atlanta Phoenix Birmingham San Antonio Tucson Autres conditions : Région 1...
  • Page 18 IV. MISE EN SERVICE Normes de mise en service Avant la mise en service Examiner Description Pour maximiser le rendement du climatiseur, tous les conduits d'aération intérieurs Emplacement et extérieurs doivent être exempts d'obstructions. Examiner attentivement l'emplacement du climatiseur. Les obstructions intérieures peuvent comprendre, entre autres, les meubles, les rideaux ou les plantes.
  • Page 19: When Service Is Required

    If you should have any matters which are not resolved by your CONSIGNES DE MISE À LA TERRE call 1-800-NAT-LSVC (1-800-628-5782) inside USA or 319- local Amana dealer, or if you would like information on other UNE TEMPÉRATURE ÉLEVÉE CONSTITUE 622-5511 outside USA. Warranty service must be per- heating and cooling products, kitchen appliances or acces- UN DANGER POUR LA SANTÉ...
  • Page 20: Amana Appliances Amana, Iowa

    FULL FIVE YEAR WARRANTY ON SEALED SYSTEM COMPONENTS propriétaire FIRST YEAR Amana will repair or replace, free of charge, any part which is defective due to workmanship or materials. SECOND THROUGH FIFTH YEAR Amana will replace, free of charge, any defective sealed system component (evaporator, capillary lines,...
  • Page 21: Español

    II. Desempacado ..........22 III. Requisitos eléctricos ........22 IV. Instalación ............. 23 V. Cuidado y mantenimiento normales ..34 EN NINGÚN CASO AMANA APPLIANCES SE VI. Instrucciones generales de operación ..35 HARÁ RESPONSABLE DE DAÑOS VII. Controles ............35 Antes de llamar para solicitar servicio ....
  • Page 22 Para obtener más información acerca de éste u otro eléctricas, esta unidad debe estar conectada a producto Amana, visite nuestro sitio Web en tierra. Bajo ninguna circunstancia corte o quite www.amana.com la punta redonda de conexión a tierra de la clavija.
  • Page 23 IV. INSTALACIÓN Requisitos de instalación Antes de comenzar la instalación Considere Descripción Para que el aire acondicionado funcione apropiadamente todas las ventilas, Ubicación dentro y fuera, deben estar libres de obstrucciones. Estudie minuciosamente la ubicación de la instalación. Las obstrucciones en el interior incluyen, entre otras, muebles, cortinas o plantas.
  • Page 24 ¿Tiene el tamaño correcto de aire acondicionado para el tamaño de habitación que desea enfriar? Consulte la siguiente guía y compruébelo. Instrucciones Rochester Fargo Eugene Albany Green Bay Reno Haven Sacramento Columbus Pueblo Wichita Fresno Charlotte Flagstaff Vegas Atlanta Phoenix Birmingham San Antonio Tucson...
  • Page 25 Antes de llamar para solicitar servicio NORTE O SOMBREADA ESTE O SUR OESTE ADVERTENCIA Para reducir el riesgo de descargas eléctricas, lesiones personales o la muerte, gire el control del ventilador a la posición off (apagar) y desconecte la clavija de la unidad del tomacorriente antes de realizar alguna inspección o trabajo de mantenimiento.
  • Page 26 WRUQLOOR GH  PP GH ULHO VXSHULRU DQFODMH GHO iQJXOR GH OD WRUQLOORV GH PRQWDMH EDQGHMD LQIHULRU GHO UHIXHU]R H[WHUQR MODELOS: AAC051FRA, AAC051SRA, AAC071FRA WRUQLOORV GH  PP GH SDWD DMXVWDEOH FRUWLQDV ODWHUDOHV VXMHFLyQ GH OD FRUWLQD UHIXHU]RV H[WHUQRV L]TXLHUGD \ GHUHFKD...
  • Page 27 Información Instrucciones de conexión a tierra V. Cuidado y mantenimiento normales importante de ADVERTENCIA seguridad Para reducir el riesgo de descargas eléctricas, lesiones personales o la muerte, Acerca de los cables de coloque el control del ventilador en la posición off (apagado) y desconecte la conexión a tierra clavija de la unidad del tomacorriente de la Acerca de la protección personal...
  • Page 28 Instrucciones de instalación a Modelo Dimensión Instalación en ventanas de casas PREPARE LA Instalación en ventanas contra través de la pared móviles tormentas VENTANA PARA LA AAC051SRA INSTALACIÓN AAC081SRA 14 1/2 7 1/2 PRECAUCIÓN AAC101SRA 22 1/2 10 5/8 AAC121SRA...
  • Page 29 INSTALE EL TUBO Y EL CORTINAS CODO DE DRENAJE LATERALES IMPORTANTE INSTALE EL EMPAQUE DE SELLO COLOQUE DE NUEVO EL BASTIDOR EN LA CAJA EXTERIOR Modelos: AAC051SRA, AAC081SRA, AAC101SRA, AAC121SRA AAC141SRA, AAC182SRA y AAC202SRA IMPORTANTE PREPARE LA UNIDAD PARA LA INSTALACIÓN Precaución Nota...
  • Page 30 INSTALE LA CAJA EXTERIOR ENSAMBLE LAS EN LA VENTANA CORTINAS Y EL RIEL SUPERIOR Nivel Hoja de la ventana PREPARE LA Instalación en ventanas contra Instalación en ventanas de casas tormentas móviles VENTANA PARA LA INSTALACIÓN No se incluye el ANTEPECHO ensamble de la cortina para...

This manual is also suitable for:

Aac121sraAac081sraAac141sraAac182sraAac202sraAac101sra

Table of Contents