If a fault is detected the boiler will be blocked.
This will be refl ected, by an alternate display of
Good, with an
a number code.
You can try to reset the boiler by pressing the
Reset key once. If the problem remains please
contact your installer and inform them about
the fault and give them the number code.
If you discover any leaks from the boiler
contact your installer.
We advise you to obtain a service contract
with your installer for regular maintance and
adjustment to keep your boiler safe and in
good condition.
The casing of the boiler consists of plastic
parts which can be cleaned with a normal non
abrasive cleaning agent.
Periodic cleaning of the condensate collection and
disposal system must be carried out.
Before putting the boiler into operation after
periodic cleaning fi ll the condensate trap with
1.27 cups / 300 ml of water.
Step 1: Condensate trap
- fi rst remove the screw (7);
7
- pull the condensation cup (8) downwards, out
of the condensate tray
Check this for impurities. If there are no impurities
it is not necessary to clean the condensate cup;
- check the O-ring (9) of the cup and replace it if
necessary;
- clean the parts by fl ushing it with clean water;
- grease the O-ring again with acid free O-ring
grease to make fi tting easier;