If a fault is detected the boiler will be blocked.
This will be reflected, by an alternate display of
Good, with an
a number code.
You can try to reset the boiler by pressing the
Reset key once. If the problem remains please
contact your installer and inform them about
the fault and give them the number code.
If you discover any leaks from the boiler
contact your installer.
We advise you to obtain a service contract
with your installer for regular maintance and
adjustment to keep your boiler safe and in
good condition.
The casing of the boiler consists of metal
and plastic parts which can be cleaned with a
normal non abrasive cleaning agent.
Periodic cleaning of the condensate collection and
disposal system must be carried out.
9
Before putting the boiler into operation after
periodic cleaning fill the condensate trap with
1.27 cups / 300 ml of water.
Step 1: Condensate trap
-
First remove the condensation cup (7); Check
this for impurities. If there are no impurities it
10
is not necessary to clean the condensate cup
8
-
Grease the O-rings again with acid free O-ring
grease to make fitting easier;
-
If there is a leak at the condensation cup (7) or
tray (9) the complete condensate trap unit (10)
has to be replaced by S4451610;
7
Step 2: Refitting is done in reverse order.
Note that all gaskets seal completely.
E
of Error or a BL of Blocking and

Hide quick links: