E02
Power Sensor did not pair with Speed Sensor correctly.
(This error only occurs after Device Pairing was not
completed satisfactorily.)
E03
Battery low on Console or Speed Sensor
Interference from the adjacent area
E04
Battery low on Console or Power Sensor
Interference from the adjacent area
E07
Tilt Sensor Calibration was not done.
E08
Tilt Sensor Calibration is incorrect or out of date
E09
USB disabled due to low battery
E10
No signal from Power Sensor
E12
EEPROM error
E13
Power Sensor is paired to the wrong Speed Sensor.
E14
Console wireless module not able to transmit/receiv
Push the pairing button on the back of the Console,
Speed Sensor and Power Sensor (if applicable) and try
the Device Pairing procedure again.
Replace all batteries, and try the Device Pairing
procedure again.
Do a Battery Level check.
Turn off any television, AM radio, microwave, or
computer within 6 feet (2 meters) of the bike, or move
the bike.
Do a Battery Level check.
Turn off any television, AM radio, microwave, or
computer within 6 feet (2 meters) of the bike, or move
the bike.
Go to Service Mode menu,C- - submenu, C01 option.
Call StairMaster Customer Care.
Go to Service Mode menu, C- - submenu, C01 option.
Call StairMaster Customer Care.
Replace Console batteries, and go to Service Mode,U- -
submenu,U02 option.
Change the Brake position and pedal the bike for a few
seconds to turn on the Power Sensor.
Remove the console batteries and install them again. If
that does not work, call StairMaster Customer Care.
Do the Device Pairing procedure again.
Replace console. Call StairMaster Customer Care.