4-3 TC Menu
4-3-6 Inserting VITC input source
(VITC)
Press the [F10] (VITC) button to select the VITC
source to be written in the video signal AUX data area.
TCG: Inserts values generated by the internal time
code generator into the VITC.
V IN: Inserts the VITC from the video input signal
directly.
4-3-7 Selecting CTL Display
Mode (TAPE TIMER)
Press the ALT button, then the [F1] (TAPE TIMER)
button to select a 12-hour or 24-hour clock for the
CTL display.
+/–12H: 12-hour clock
24H: 24-hour clock
4-3-8 Presetting Pull Down Time
Code (PDPSET MENU)

(when HKDV-507/507D is installed)

To preset the pull down time code when this VTR is
operated in 23.98PsF/ 24PsF mode, follow the steps
below.
4
2,7
3
1
1
Press the TC button, then press the ALT button.
The ALT+TC menu appears.
4-26
Chapter 4 Menu Settings
5
6
2
Press the [F2] (PDPSET MENU) key.
The PDPSET menu appears.
REMAIN-T
CH.COND
P R E S E T
M O D E
L 113min
G R E E N
2 4 F
2 4 F T C
P D T I M E
00
00
S E T
Ó
3 0 F T C
00
00
Ó
P D T C
D F / N D F
N D F
3
Press the [F1] (PRESET MODE) key to select 24F
or 30F time code to be preset. The selected time
code is framed with the thick line.
24F: Presets the 24 frames time code. The A
frame of the pull down sequence is preset.
30F: Presets the 30 frames time code. The A
frame of the pull down sequence is preset.
4
•When 30F is selected in the step 3,
Press the [F6] (PDTC DF/NDF) key to select DF
or NDF.
This selection is effective only for 30F time code.
DF: Drop frame mode
NDF: Non-drop frame mode
auto: The unit switches the running mode (DF/
NDF) automatically according to the frame
frequency of the unit. When the frame
frequency is 23.976 Hz, the unit switches to the
drop frame mode and switches to the non-drop
frame mode when it is 24 Hz.
•When 24F is selected in the step 3,
Skip this step.
5
Enter the time code data in the data entry window
with numeric keys.
R E M A I N - T
C H . C O N D
P R E S E T
L 1 1 3 m i n
G R E E N
M O D E
2 4 F
2 4 F T C
P D T I M E
00
00
S E T
Ó
µ
3 0 F T C
00
00
Ó
µ
P D T C
D F / N D F
D F
PDPSET
T C R 0 0 : 0 0 : 0 0 : 0 0
00
00
µ
ß
ƒ
00
00
µ
ß
ƒ
E X I T
P D P S E T
Data entry
0 1 0 0 3 0 0 0
window
T C R 0 0 : 0 0 : 0 0 : 0 0
00
00
ß
ƒ
00
00
ß
ƒ
E X I T