ZTS-100 can be configured as either "Frequently Listening Routing Slaves" (FLiRS) or "Always
Listening" node and it will distinguish the power source (batteries or 24Vac) automatically and
switch to appropriate mode during inclusion stage.
FLiRS node type is targeted for battery operated applications and will enter sleep mode frequently in
order to conserve battery consumption that can provide flexibility if there is out of 24Vac power line.
Always Listening node type is targeted for AC power operated applications and it can act as a
repeater, which will re-transmit the RF signal to ensure that the signal is received by its intended
destination by routing the signal around obstacle and radio dead spots.
Application for out of 24Vac power line:
1. Install AAx4pcs batteries and power up the unit.
2. Execute the step of "Delete (Exclusion) ZTS-100 from Gateway / Controller Z-Wave network".
3. Execute the step of "Add (Inclusion) ZTS-100 to Gateway / Controller Z-Wave network".
4. ZTS-100 will be configured as FLiRS operation after step 3 (inclusion).
ZTS-100 will not response Z-Wave command very quickly as it will enter sleep mode
frequently in order to conserve battery consumption.
Application for 24Vac power line:
1. Connect 24Vac power and power up the unit, make sure AAx4pcs batteries has been removed.
2. Execute the step of "Delete (Exclusion) ZTS-100 from Gateway / Controller Z-Wave network".
3. Execute the step of "Add (Inclusion) ZTS-100 to Gateway / Controller Z-Wave network".
4. ZTS-100 will be configured as Always Listening operation after step 3 (inclusion).
It can install AAx4pcs batteries for power backup purpose after step 4.
Important:
It is not allow changing ZTS-100 operation mode by change of power source. It is need to follow
the above steps to change ZTS-100 operation mode.
Add (Inclusion) ZTS-100 to Gateway / Controller Z-Wave network
Step Procedure / Description
Gateway / Controller device should
entry the inclusion mode.
Press and hold "Home" key for 2
1
seconds to entry the Add
(Inclusion) / Delete (Exclusion)
Mode.