Sony CCU-50P Operation Instructions Manual page 15

Camera control unit
Table of Contents

Advertisement

Each time you press the CHARACTER button, another
page of results is displayed in turn.
DM board
CAM Video: Reception status of the video signals
from the camera.
Skin Gate: Reception status of the Skin gate signal
from the camera
TRIAX Comp.: Cable compensation type selected
for the triaxial cable (automatic/manual)
TRIAX Step: Compensation step of the triaxial cable
(step indication in the circuit) (The cable length may
not be displayed correctly.)
Power: DM board power supply status
TR board
Prompter: Setting status of the prompter line
Tone: Tone signal status
Incom: Demodulating status of the intercom line
CHU Data: Data reception status from the camera
Power: Power supply status of the TR board
AT board
Reference: Operation mode of the phase adjustment
Gen Lock: Locking status
BATT Volt: Voltage of the coin battery supplied with
the AT board
CCU Mode: Operation mode of the CCU
PLD Config.: Configuration result status of the PLD
mounted on the AT board
CCU Power: CCU power supply type (AC/DC) and
power supply status
AU board
CAMERA Mic: Input status of the camera
microphone (on/off)
CAMERA Line: Pathway of the intercom signal of
the camera (ENG/PROD/PRIV)
CCU FRONT Mic: Input status of the unit's
microphone (on/off)
CCU FRONT Line: Pathway of the connection of the
intercom signal of the unit (ENG/PROD/PRIV)
Power: Power supply status of the AU board