Operation; Trigger Lock; Pressure Relief Procedure; Pressure Control Knob Settings - Magnum 262800 Operation

Airless sprayers
Hide thumbs Also See for 262800:
Table of Contents

Advertisement

Operation

See Operation manual 312001 for basic information on
sprayer set-up, flushing, and storage.

Trigger Lock

Always engage the trigger lock when you stop spraying
to prevent the gun from being triggered accidentally by
hand or if dropped or bumped.
ti8923a
Trigger Locked SG10
ti8908a
Trigger Locked SG20,
SG2, SG3, SGPro

Pressure Control Knob Settings

High Pressure
Spray
NOTE: To select function, align symbol on pressure control knob with setting indicator on sprayer.
312667H
ti8922a
Trigger Unlocked SG10
ti8909a
Trigger Unlocked SG20,
SG2, SG3, SGPro
Low Pressure
Spray

Pressure Relief Procedure

Follow this Pressure Relief Procedure whenever you
stop spraying and before cleaning, checking, servicing,
or transporting equipment.
1. Turn power switch OFF and unplug
power cord.
2. Turn Prime/Spray valve to
PRIME to relieve pressure.
3. Hold gun firmly to side
of pail. Trigger the gun
to relieve pressure.
4. Engage trigger lock.
NOTE: Leave Prime/Spray valve in the PRIME position
until you are ready to spray again.
If you suspect the spray tip or hose is clogged or that
pressure has not been fully relieved after following the
steps above, VERY SLOWLY loosen tip guard retaining
nut or hose end coupling to relieve pressure gradually,
then loosen completely. Clear hose or tip obstruction.
Read Unclogging Spray Tip instructions in the Sprayer
or Gun Operation manual.