GENERAL INJECTORS TABLE
Kind of gas
Nozzle
mm/100
Natural
135
115
97
72
L.P.G.
95
Butane
85
Propane
65
50
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o IMPORTANT: The minimum flow adjustment process must
be completed before the appliance is next used.
o Unscrew the injector (B) and replace it
with the stipulated injector for the new gas
supply (see table below).
Burners
Wok
Rapid
Semi-rapid
Auxiliary
Wok
Rapid
Semi-rapid
Auxiliary
Power (in watts)
Max.
Min.
3500
1700
3000
700
1750
400
1000
350
3500
1700
3000
700
1750
400
1000
350