Alliance Laundry Systems SE5130 Service
Alliance Laundry Systems SE5130 Service

Alliance Laundry Systems SE5130 Service

Commercial stacked dryers
Table of Contents

Advertisement

Quick Links

Commercial
Stacked Dryers
Metered and Nonmetered
Refer to Page 3 for Model Numbers
Part No. 53277R2
www.comlaundry.com
January 2002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SE5130 and is the answer not in the manual?

Questions and answers

Summary of Contents for Alliance Laundry Systems SE5130

  • Page 1 Commercial Stacked Dryers Metered and Nonmetered Refer to Page 3 for Model Numbers Part No. 53277R2 www.comlaundry.com January 2002...
  • Page 2: Table Of Contents

    All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 3: Section 1 - Safety Information

    • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the product is properly grounded and to reduce the risk of fire, electric shock, serious injury or death. W006R1 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 4: Locating An Authorized Servicer

    Locating an Authorized Servicer Alliance Laundry Systems is not responsible for personal injury or property damage resulting from improper service. Review all service information before beginning repairs. Warranty service must be performed by an authorized technician, using authorized factory parts. If service is required after the warranty expires, Alliance Laundry Systems also recommends contacting an authorized technician and using authorized factory parts.
  • Page 5: Section 2 - Introduction

    When calling or writing about your product, be sure to mention model and serial numbers. Model and serial numbers are located on nameplate(s) as shown. DRY912P NAMEPLATE 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 6: Model Identification

    RG6392 RE6330 RG6390 RE6232 RH6292 RE6132 RH6192 RE6130 RG6190 RE5232 RG5292 RE5230 RG5290 RE5132 RG5192 RE5130 RG5190 EE5511 EG5121 EE5510 EG5120 EE5111 EG5020 EE5110 EG5010 EE1510 EG1520 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 7: How Your Dryer Works

    The heated air moves through the heater duct and into the cylinder, where it circulates through the wet load. The air then passes through the lint filter, air duct, and exhaust fan, where it is vented to the outdoors. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 8: Section 3 - Grounding

    (Gas and Electric Models - with painted Exhaust Fan Cover) Refer to Figure 2 (Ground wire not used on unpainted covers) GROUND WIRE DRY832S GROUND WIRE Figure 1 GROUND WIRE DRY833S Figure 2 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 9: Neutral At Terminal Block To Terminal Block Bracket And From Terminal Bracket To Control (Electric Models Only)

    TO CONTROL HOUSING. WALL RECEPTACLE POLARITY CHECK (Gas Models Only) Refer to Figure 4 NOTE: For determining GROUND the correct polarity of a wall receptacle. NEUTRAL GROUND V.A.C. WIRE NEUTRAL V.A.C. SIDE V.A.C. DRY945S Figure 4 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 10: From Terminal Block Bracket To Accumulator Bracket Or Timer (Depending On Model) To Cabinet Top To Control Panel (Metered And Non-Metered Models )

    6. FROM TERMINAL BLOCK BRACKET TO CABINET TOP, FROM CABINET TOP TO TIMER AND CABINET TOP TO CONTROL PANEL (Card Reader Models) GROUND WIRE GROUND WIRE DRY947S Figure 6 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 11: Section 4 - Service Procedures

    Remove control panel. Refer to Paragraph 7. b. Reach in through control panel opening and remove screws holding accumulator and DRY449S mounting bracket to control cabinet. Figure 8 c. Disconnect wires from accumulator. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 12 Switch C (if present) = “infinite” (open) RATCHET WHEEL TIMING RATCHET WHEEL DRY958S SWITCH LEVER SWITCHES SWITCH DRY959S LEVER 3 Switch Accumulator 2 Switch Accumulator Figure 9 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 13 8. Rotate timer to “OFF” position. “Infinite” (open) reading should be found between L1 and M and between L1 and H. NOTE: Timer motor power is supplied through M terminal. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 14: Push-To-Start Switch

    3. Meter should give “no reading” from L1 to C or from L2 to C in DeLICATE or FLUFF. 4. Meter should give “no reading” from C to 1 in DELICATE. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 15: Front Panel And Panel Seal

    2. Set meter to read Ohms and apply meter probes on switch terminals with door closed. You should get “zero” reading. 3. Open door. Meter should read “infinite. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 16: Indicator Light

    DOOR HANDLE Refer to Figure 13 a. Remove loading door. Refer to Paragraph 14. b. Remove screws holding handle to door and separate panels. Refer to Figure 13. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 17: Lint Filter

    Refer to Figure 14 bracket and remove terminal block. a. Terminal Block - Electric Models (1) Remove access plate on rear of dryer. (2) Remove all wires from terminal block. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 18 (2) Remove strain relief holding power cord to cabinet. (3) Remove screw holding power cord ground wire to terminal block bracket. NOTE: Reconnect ground wire into same hole in bracket when reinstalling power cord. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 19: Burner System Operation

    (3) Ignition is made and the heat from the burner flame causes the flame sensor contacts to remain open. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 20: Burner System Components (Gas Models) Silicon Carbide (Glow Bar) Ignition

    SCREW HEAT SHROUD BURNER HOUSING LIMIT THERMOSTAT BURNER TUBE SCREW SENSOR ATTACHING DISCONNECT SCREW BLOCK INLET TUBE FLAME SENSOR NIPPLE VALVE D241S UNION Figure 16 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 21 CAREFULLY remove burner tube and igniter assembly out through front NOTE: If meter registers any other readings than of dryer. listed above, the respective coil should be replaced. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 22 (3) If 58823 igniter, remove Phillips head screw holding igniter and ceramic block to burner tube. Refer to Figure 18. NOTE: Igniters 55438 and 58823 are not interchangeable. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 23 40 Ohms, replace the igniter. SCREW HEAT SHROUD BURNER HOUSING LIMIT THERMOSTAT BURNER TUBE SCREW SENSOR ATTACHING DISCONNECT SCREW BLOCK INLET TUBE FLAME SENSOR NIPPLE VALVE D241S UNION Figure 19 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 24 120 VOLT, 60 HERTZ ELECTRICAL SUPPLY LINE HOLDING SECONDARY SECONDARY COIL COIL BOOSTER SENSOR COIL HOLDING COIL IGNITOR BOOSTER COIL D268S D267S WIRING SCHEMATIC Figure 20 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 25: Burner Housing

    (2) Remove wires from thermostat. NOTE: Refer to appropriate wiring diagram when rewiring thermostat. (3) Remove screws holding thermostat to burner housing. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 26: High Or Low Thermostat

    THERMOSTAT GAS VALVE HANDLE ELEMENT BURNER ATTACHING TUBE SCREWS SCREW BURNER HOUSING D399S BASE HEX HEAD SHUTTER SCREW LIMIT THERMOSTAT DRY854S GAS MODELS ELECTRIC MODELS Figure 22 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 27: Front Air Duct

    NOTE: Refer to appropriate wiring diagram when rewiring thermostats. d. Remove screws holding fan cover to housing DRY958S SWITCH LEVER SWITCHES Figure 23 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 28: Motor And Exhaust Assembly

    NOTE: When removing motor and exhaust assembly, it may be necessary to remove wire clips from right side of cabinet to provide clearance. f. Disconnect wires from motor switch. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 29: Impeller And Housing

    7/8" .6 pt. socket. d. Remove screws and washers holding exhaust housing to the motor mounting bracket. Refer to Figure 26. D402S EXHAUSTING HOUSING ATTACHING SCREWS Figure 26 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 30: Motor

    Remove one or two screws holding switch to motor. b. Disconnect internal motor leads from switch terminals. NOTE: Refer to appropriate wiring diagram when rewiring motor switch. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 31: Motor And Idler Pulley Assemblies

    Refer to Figure 28. CABINET ATTACHING c. Disconnect belt. SCREWS NOTE: Front air duct will be removed with the bulkhead unless previously removed in Paragraph DRY858S Figure 28 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 32: Cylinder Belt

    (Installed with cupped surface against seal) BULKHEAD Seal must be positioned under MOTOR flanged edge PULLEY SPRING DRY862S Figure 30 DRY861S CYLINDER GLIDE ATTACHING SCREWS Figure 29 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 33: Cylinder Assembly

    Sealant (obtain locally). This is D403SE1A ® accomplished by apply a bead of 3M-1300 Sealant around the entire flanged area where the felt seal Figure 32 contacts the bulkhead. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 34 QQQQQQQQQ MOUNTING BRACKET @@@@@@@@@ QQQQQQQQQ @@ @@ QQ QQ @@@@@@@@@ QQQQQQQQQ SPRING @@@@@@@@@ QQQQQQQQQ SEAL HEATER STRAP HEAT SHIELD CYLINDER ROLLERS DRY864S HEX HEAD SCREWS Figure 33 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 35: Cylinder Rollers And Roller Shaft

    TO REMOVE HEATER BOX FROM REAR BULKHEAD a. Refer to Figure 35 for removal. REAR BULKHEAD HEATER BOX ATTACHING SCREWS ROLLERS ROLLER WASHER DRY955S HEATER Figure 34 DRY866S Figure 35 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 36: Heat Shield

    ATTACHING SCREWS of cabinet and lift cabinet off base. GROUND SCREW HEAT SHIELD ATTACHING SCREWS EXHAUST DUCT SCREW DRY867S Figure 36 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 37: Section 5 - Adjustments

    DO NOT slide the dryer across the floor once the leveling legs have been DRYER extended as the legs and base could become BASE damaged. LOCKNUT RUBBER LEVELING DRY960S Figure 37 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 38: Burner Flame (Gas Models)

    After proper flame is obtained, tighten air shutter lockscrew securely. WASHER PHILLIPS HEAD SCREW APPLY PRESSURE HERE SUPPORT ACCESS DOOR DRY951S Figure 38 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 39: Section 6 - Gas Burner Conversion Procedures

    Sticker MANOMETER 10 ± 1.5 INCHES 1 - 60518 L.P. Gas Stickers 1 - 4-88-25R1 Instructions Block Open Plug Burner Orifice Spud DRY962S PRESSURE DRY961S Figure 39 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 40: Installing The No. 458P3 Kit

    Install No. 60517 “Valve Converted to L.P. blocks. Refer to Figure 40. Gas” Sticker to top side of gas valve so it covers the gas valve part number. Refer to Figure 40. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 41 Figure 40. (2) Connect a “U” tube manometer (or similar SHUTTER pressure gauge) to the pressure tap. Refer to Figure 43. GAS VALVE DRY965S PRESSURE TAP Figure 43 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 42 Be sure and observe at least two complete ignition and burn cycles before reinstalling access door. q. Reinstall access door and screw. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 43: No. 459P3 Natural Gas Conversion Kit For "Eg" Models/Series Dryers

    1 - 4-88-26R1 Instructions Figure 44 Vent Screw Burner Orifice Spud DRY966S NOTE: Kit will convert one gas valve; 2 kits are needed for converting upper and lower units. 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 44: Installing The No. 459P3 Kit

    Refer to Figure 38. j. Apply the No. 60512 Conversion Plate to the inside of the loading door opening above the nameplate. Refer to Figure 42. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 53277...
  • Page 45 Check the gas line connection for gas leaks with a soapy solution. WARNING To reduce the risk of explosion and fire, do not use an open flame to check for gas leaks! 53277 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...

Table of Contents