Air Pressure Switch; Water Pressure Switch; Safety Valve - Ferroli F30 Installation, Servicing And User Instructions Manual

Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control
Table of Contents

Advertisement

7.05 Air pressure switch

• Isolate electricity
• Remove outer case two screws bottom rear corners
• Open room sealed department
• Remove the two screw "A" xin air pressure switch
• Disconnect electrical leads "B"
• Remove pressure sensin tubes white=D; Red=C
• Note relevant positions of all connections and
replace in reverse order
7.06
.H.W. temperature sensor or entral Heating Temperature Sensor
9
• Isolate electricity and water supplies
• Remove outer case two screws bottom rear corners
• Remove the two securin screws and lower control panel
• Identify the sensor from
• Disconnect electrical connection to the sensor
• Drain the affected service either D
nscrew the sensor
• Replace in reverse order
7.07 Water ressure Switch
• Isolate electricity and water supplies
• Remove outer case two screws bottom rear corners
• Remove the two securin screws and lower control panel
• Identify the switch from
• Disconnect electrical connections
• Drain the boiler
nscrew the sensor
• Replace in reverse order
7.0 Sa et
al e
• Isolate electricity and water supplies
• Remove outer case two screws bottom rear corners
• Remove the two securin screws and lower control panel
• Identify valve from
• Drain the boiler
• Release the outlet union to the valve and
union connection
• Remove the valve outlet ttin
• Replace in reverse order
ure 9
or C
9
ure 9
note positions to the switch
9
9
ater pressure switch
undo the valve
C
sensor
afety valve
A
Fig. 28
D
sensor
9
Fig. 2
31