FERROLI F 30 B wall-mounted gas fired, condensing combination boiler INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE FOR THE UNITED KINGDOM AND EIRE G C N° 47-267-36...
Page 2
“This record must be completed and left with the end user”. Ferroli is a member of the Benchmark initiative and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
Please read this manual carefully and keep it for future reference. FERROLI F 30 B is a high-efficiency condensing appliance for heating and hot water production run- ning on natural or liquefied petroleum gas (configurable at the time of installation) and regulated by an advanced microprocessor control system.
Ferroli F 30 B 1.2 Control panel Fig. 1 The boiler is designed for use with two types of gas: natural gas NG or propane (LPG). The type of gas can be selected when purchasing the boiler or the appliance can be converted later on site by a competent person.
Ferroli F 30 B 1.3 Operating instructions Ignition • Open the gas isolation valve upstream of the boiler. • Purge the air from the pipe upstream of the gas valve. • Ensure power is on to appliance. • Turn the switch A (fig. 1) to the ON position.
) illuminates repeatedly, contact an approved Férroli service engineer. For other faults, refer to section 3.4 “Troubleshooting.” Before calling the Ferroli service centre, check that the problem is not due to an installation error or a problem with the gas/electricity or low water pressure in the system.
Ferroli F 30 B 1.7 Time Clock A 24 hour time clock is fitted to the boiler to control the central heating, this will come into operation when the selector switch “F” is turned to the position marked “auto”. Slide switch: set clock - auto - set programme Display.
Ferroli F 30 B 2. INSTALLATION 2.1 General Instructions This device must only be used for the purpose for which it is specially designed. This unit is designed to heat water to a temperature below boiling point and must be connected to a hea- ting system and/or a water supply system for domestic use, compatible with its performance, characteristics and its heating capacity.
Ferroli F 30 B 2.2 Boiler location The unit’s combustion circuit is sealed off from the installation room. The installation room must be sufficiently well ventilated to prevent any dangerous conditions from forming in the event of even slight gas leakage. This safety standard is required by the EEC Directive no. 90/396 for all gas units, including those with a so-called sealed chamber.
Page 11
Ferroli F 30 B Make Up Water Provision must be made for replacing water lost from the sealed system. Reference should be made to BS6798, for methods of filling and making up sealed systems. There must be no direct connection between the boiler's central heating system and the mains water supply.
Ferroli F 30 B 2.3 Boiler water connections The heating capacity of the unit should be previously established by calculating the building’s heat requirement according to current regulations. For good operation and long life of the boiler, the plumbing system must be well proportioned and always complete with all those accessories that guarantee regular operation and running, room thermostat, trv’s and automatic bypass.
Page 13
7 Water treatment When treatment is used Ferroli limited only recommend the use of a proprietary brand, such as Fernox or Sentinel water treatment products, which must be used in accordance with the manufacturer’s instructions. for further information contact: Fernox Manufacturing Co.
Ferroli F 30 B 2.4 Connection to the gas system If necessary the local Gas supplier should be consulted, at the installation planning stage, in order to establish the availability of an adequate supply of gas. An existing service pipe must not be used without prior consultation with the local Gas supplier.
The current standards and local regulations must be observed. It should be noted that only Ferroli flue system and accessories should be used on this appliance, as per BS 5440 2000 and C.E. test certification.
Page 16
Ferroli F 30 B Restrictor For boiler operation, the restrictor supplied with the unit must be mounted following the instructions below. Determine the correct size of flue restrictor required. Before inserting the flue gas duct in the boiler, check that the restrictor fitted is correct and that it is correctly positioned (see fig. 9).
Ferroli F 30 B Connection with concentric flue system The unit can be connected to a concentric air/flue duct with a horizontal or vertical outlet as shown on the following drawings. Numerous accessories are available on request to meet the various installation requirements. Please refer to our “flue manual”...
Page 18
Ferroli F 30 B and cover with wall seals provided. Flue seals should be lubricated with a silicone type grease to prevent damage (grease not supplied) Vertical Outlet The total length in equivalent metres of the concentric flue must not exceed the maximum lengths stated in the...
Page 19
3. Check that the total calculated loss is less than or equal to 48 equivalent metres, i.e. the maximum permissible for this model of boiler. For further flue options please contact FERROLI or check our comprensive flue manual. Table 3 Equivalent Ref.
Page 20
Ferroli F 30 B Table of flue and accessories The stated loss values refer to genuine Ferroli flue accessories. Terminal Position...
Connection to collective flues or single flues with natural draught If you are then going to connect the Ferroli F 30 B boiler to a collective flue or a single flue with natural draught, the flue must be expressly designed by professionally qualified technical personnel in confor- mity with the standards and rules in force.
Page 23
Ferroli F 30 B Condensate discharge Where possible the condensate should discharge into an internal soil pipe or waste system. The minimum pipe diameter required is 22 mm, a trap has already been fitted to the appliance with a flexible tail to facilitate the connection to the condensate discharge pipe.
3. SERVICE AND MAINTENANCE 3.1 Adjustments All adjustment and conversion operations must be carried out by a qualified and trained engineer such as a Ferroli Service Engineer. FERROLI declines any responsibility for damage or physical injury caused by unqualified and unauthorized persons tampering with the device.
Page 25
Ferroli F 30 B Adjustment potentiometers P1 = C.H. temperature adjustment P2 = D.H.W. temperature adjustment P3 = C.H. output adjustment P4 = Ignition gas pressure adjustment Fig. 16 P5 = Minimum gas pressure adjustment Adjusting maximum output for central heating system (fig. 16) This adjustment must be carried out electronically using the “P3”...
Ferroli F 30 B FERROLI Limited accepts no liability for damage to property or personal injury resulting from tampering with the boiler by unauthorised persons. To convert the boiler from Nat Gas to LPG and vice versa, the main burner injectors must be replaced.
Ferroli F 30 B Close the boiler isolation gas cock and turn off the electricity to the boiler. Important: If the boiler is not to be used for lengthy periods during the winter, to avoid frost damage, you are recommended to drain the water from the circuits (domestic hot water and central heating).
Page 28
Ferroli F 30 B Servicing procedure Visually check boiler for correct installation and flueing. Isolate electricity supply & check fuse is 3amp. Remove case by undoing the two screws located at the bottom rear corners, lift slightly and pull forward.
Ferroli F 30 B Cleaning the boiler and burner The body and burner must not be cleaned with chemical products or wire brushes. Special care must be taken over all the sealing systems pertaining to the sealed chamber (gaskets, cable clamps, etc.). In addition, it is necessary to pay attention after performing all these operations to check and carry out all the phases of ignition and thermostat operation, the gas valve and circulation pump.
Page 30
Ferroli F 30 B The burner will light at ignition burner pressure, automatically range rating itself up to the heating load, then modulating down when the boiler reaches the desired flow temperature. When the central heating is satisfied the burner will go off and the fan stops i.e. stand-by mode.
Page 31
Ferroli F 30 B MF03.1 PCB When operating the C.H. the following lights should be on: 4, 5 and flame on light. For D.H.W. the following lights should be on: 3, 5 and flame on light. If the boiler works for C.H. but not D.H.W., or vice versa, a number of components must be functioning and can, therefore, be eliminated as being at fault.
Page 32
Ferroli F 30 B both are adjustable by the controls on the facia and because the boiler features automatic range rating no adjustments need to be made. Electro mechanical relays control pump operation and demand. Air pressure switch Operating at 230 V AC and situated next to the fan. Different coloured tubes connect the switch to the fan.
Ferroli F 30 B 4 TECHNICAL CHARACTERISTICS AND DATA 4.1 Dimensions and connections Top view 161,5 178,5 2 3 4 System flow (22 mm with isolation valve fitted) DHW outlet (15 mm with isolation valve fitted) Gas inlet (22 mm with isolation valve fitted)
Ferroli F 30 B 4.2 General view and main components Combustion chamber Gas inlet DHW outlet Cold water inlet CH flow CH return Safety valve Combustion chamber Gas injector Burner Combustion chamber insulation Copper heat exchanger for c.h. + d.h.w.
Weight empty Gas system connection 1/2” Heating system connections 3/4” Hot water circuit connections 1/2” Maximum length of separate flues D=80* (*Measurement given in equivalent linear metres – cfr FERROLI calculation system) Electrical power supply Max electrical power absorbed Protection level...
Ferroli F 30 B 4.5 Diagrams Circola H 6 m. Head available for the system Per mod Domico H [m H 2 O] Ferroli F 2.000 Q [l/h] 1.000 1.500 = Circulator speed = Boiler losses of head ...
Page 44
Should you require any assistance during the installation call our Technical Service Helpline on 08707 282 885 option 1 Should you require a service engineer to visit Call our service centre on 08707 282 885 option 2 (For U.K. and Northern Ireland) For EIRE only call HEATOVENT on 014508166 Phone numbers:...