Procedure 6.2 - Replacing The Limit Switches, Actuator Shaft Or Switch Bracket - Precor C944 Service Manual

Hide thumbs Also See for C944:
Table of Contents

Advertisement

Procedure 6.2 - Replacing the Limit Switches, Actuator Shaft
Note:
The limit switches and the actuator shaft are mounted on the switch bracket (see Diagram 4.2).
WARNING
Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood.
Procedure
1.
Remove the hood.
2.
If you are removing the actuator shaft...
THEN...
Skip to Step 12 (to remove the actuator
shaft), Step 6 (to remove
the down limit switch) or Step 9 (to
remove the zero sense switch.
Removing the Upper Limit Switch
WARNING
When power is applied to the treadmill, the wires connected to the upper and lower limit switches
carry high voltage. Turn off the treadmill and unplug the power cord from the wall outlet before
you perform the following steps.
3.
Carefully remove the red wires from the upper limit switch.
Note:
See Diagram 6.2 for limit switch wiring.
4.
Remove the screws and washers that secure the limit switch to the switch bracket.
5.
If you are removing more than one limit switch...
THEN...
Continue with the next step to
remove the down limit switch or
Step 9 to remove the zero sense
switch
or Switch Bracket
OTHERWISE...
Continue with the next step.
OTHERWISE...
Skip to Step 11.
C944 Treadmill
Page 30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents