Procedure 6.1 - Replacing The Electronic Console And Crank Handle, Upper Pca Or Keypad - Precor 905e Service Manual

Hide thumbs Also See for 905e:
Table of Contents

Advertisement

Procedure 6.1 - Replacing the Electronic Console and Crank
Wear an anti-static device (such as a wrist strap) when you perform this procedure. Anti-static
kits can be ordered from Precor Customer Service (Precor part number 20024-101).
Removing the Electronic Console
Place the magnetic safety key in the OFF position, then unplug the treadmill from the wall
1.
outlet.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One of the Residential Treadmill Service Manual.
2.
Remove the crank handle and set it aside (see Diagram 6.1).
3.
Remove the bolts and washers that secure the electronic console to the upper handrail
clamp.
Diagram 6.1 - Removing the Crank Handle
4.
Disconnect the ribbon cable from the upper PCA (see Diagram 6.2).
5.
If you are going to re-install the electronic console (without replacing either the upper PCA
or display label and keypad) . . .
Handle, Upper PCA or Keypad
905E, 9.1, 9.10 Treadmills