High Voltage Transformator

If the primary winding is supplied
with a mains voltage of 230 V,
following voltages are induced
into secondary windings:
-3.1 V as low voltage, directly
connected with the heating
winding of the magnetron for
heating the cathodes
-2,750 V as high voltage,
connected with the voltage
doubling
Thus the high-voltage
transformer is placed in the
appliance.
The sticked-on rubber parts are
indispensable for the prevention
of vibrations to the casing.
created by TSE-N, Reiner Kurzke
The high-voltage capacitor
consists of three windings:
-a primary winding
-a secondary high-voltage
winding
-a secondary low voltage
winding