(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal
and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches,
(5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation
and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual
before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be per
formed on each oven prior to release to the owner.

Before Servicing

Before servicing an operative unit, perform a microwave emission check as per the Microwave Measurement
Procedure outlined in this service manual.
If microwave emissions level is in excess of the specified limit, contact Electrolux HOME PRODUCTS, INC.
immediately.
If the unit operates with the door open, service person should 1 ) tell the user not to operate the oven
and 2) contact Electrolux HOME PRODUCTS, INC. and Food and Drug Administration's Center for
Devices and Radiological Health immediately.
Service personnel should inform Electrolux HOME PRODUCTS, INC. of any certified unit found with
emissions in excess of 4mW/cm2. The owner of the unit should be instructed not to use the unit until the
oven has been brought into compliance.

Danger Caution HIGH VOLTAGE

Do not energize a microwave oven with the outer case cabinet removed, because a microwave oven
generates High Voltage in the circuit.
If you intend to operate the oven employing the high frequency switching power converter circuit, you should
take special precautions to avoid an electrical shock hazard.
The high voltage transformer, high voltage capacitor and high voltage diode have energized high voltage
potential approx. 8 KV.
The aluminium heat sink is connected to the switching power transistor Collector pole, and has an energized
high voltage potential approx. 650V peak.
DO NOT ACCESS THE HIGH VOLTAGE TRANSFORMER , HIGH VOLTAGE CAPACITOR , HIGH VOLTAGE
DIODE AND HEAT SINK WHEN THE POWER SUPPLY IS CONNECTED TO AN ELECTRICAL OUTLET.
Basic Information
1-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ei30bm55hsEi30bm55hzEi30bm55hw

Table of Contents