HEM-7080-C1_B_M.fm Page 2 Tuesday, March 9, 2010 9:05 AM Contents Before using the unit Introduction ................3 Important Safety Information..........4 1. Overview ................6 2. Preparation ............... 9 2.1 Installing/Replacing the Batteries........9 2.2 Setting the Date and Time .......... 11 Operating instructions 3.
HEM-7080-C1_B_M.fm Page 3 Tuesday, March 9, 2010 9:05 AM Before using the unit Introduction Thank you for purchasing the OMRON HEM-7080 Intellisense Upper Arm Blood Pressure Monitor. The OMRON HEM-7080 Intellisense is a fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly.
• Do not inflate the arm cuff over 299 mmHg. (Optional AC Adapter Usage) • Use only AC adapter specified by Omron dealers. Use of unsupported adapters may damage and/or may be hazardous to the unit. Plug the AC adapter into the appropriate voltage outlet.
Page 5
HEM-7080-C1_B_M.fm Page 5 Tuesday, March 9, 2010 9:05 AM Important Safety Information • Never plug in or unplug the power cord from the electric outlet with wet hands. (Battery Usage) • If battery fluid should get in your eyes, immediately rinse with plenty of clean water.
HEM-7080-C1_B_M.fm Page 6 Tuesday, March 9, 2010 9:05 AM 1. Overview Main Unit A. Display F. User ID selection switch B. SET button (A & B) C. Morning/Evening Average G. Battery compartment H. Air jack ) buttons I. AC adapter jack (for AC D.
Page 7
HEM-7080-C1_B_M.fm Page 7 Tuesday, March 9, 2010 9:05 AM 1. Overview Display M. Systolic blood pressure U. User ID symbol (A or B) N. Diastolic blood pressure (Indicates user A or user B as O. Heartbeat symbol selected by the user to take a 1.
HEM-7080-C1_B_M.fm Page 9 Tuesday, March 9, 2010 9:05 AM 2. Preparation Installing/Replacing the Batteries Turn the main unit upside down. Slide the battery cover in the direction of the arrow while pressing the ribbed part of the cover. Install or replace four “...
Page 10
HEM-7080-C1_B_M.fm Page 10 Tuesday, March 9, 2010 9:05 AM 2. Preparation Battery Life & Replacement If the battery low symbol ( ) appears on the display, replace all four batteries at the same time. - When the battery low symbol ( ) starts to blink, you will still be able to use the unit for a short while.
HEM-7080-C1_B_M.fm Page 11 Tuesday, March 9, 2010 9:05 AM 2. Preparation Setting the Date and Time Your blood pressure monitor automatically stores up to 84 measurement values per user with date and time. To make use of the memory and average values functions: •...
Page 12
HEM-7080-C1_B_M.fm Page 12 Tuesday, March 9, 2010 9:05 AM 2. Preparation Repeat steps 2 and 3 to set the month. The month is set and the day digits flash on the display. Repeat steps 2 and 3 to set the day.
Page 13
HEM-7080-C1_B_M.fm Page 13 Tuesday, March 9, 2010 9:05 AM 2. Preparation Repeat steps 2 and 3 to set the hour. The hour is set and the minutes digits flash on the display. Repeat steps 2 and 3 to set the minutes.
Page 14
HEM-7080-C1_B_M.fm Page 14 Tuesday, March 9, 2010 9:05 AM 2. Preparation Notes on Adjusting the Date and Time Setting If you need to adjust the date and time for some reason, or if the date and time has been reset after replacing the batteries, adjust the date and time between 10:00 AM and 6:59 PM.
HEM-7080-C1_B_M.fm Page 15 Tuesday, March 9, 2010 9:05 AM Operating instructions 3. Using the Unit How to Sit Correctly When Taking a Measurement You can take a measurement on either your left or right arm. Notes: • Measurements should be taken in a quiet place and you should be in a relaxed, seated position.
Page 16
HEM-7080-C1_B_M.fm Page 16 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Notes: • Correct posture during measurement is necessary to get accurate results. • You should also try to measure your blood pressure at the same time each day. (Within 1 hour after waking up is recommended.)
HEM-7080-C1_B_M.fm Page 17 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Applying the Arm Cuff You can wrap the cuff either on your right or left arm. • Remove tight-fitting clothing from your upper arm. • Do not place the cuff over...
Page 18
HEM-7080-C1_B_M.fm Page 18 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Hold the grip on the cuff Grip securely with your hand. Fabric fastener Turn the palm of your hand upward. Apply the cuff to your left upper arm so that the blue strip is centred on the middle of your inner arm and points down the inside of the arm.
Page 19
HEM-7080-C1_B_M.fm Page 19 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit When the cuff is positioned correctly, close the fabric fastener FIRMLY. Notes: • Make certain the cuff fits snugly around your arm. • The cuff should make good contact with your skin. You should be able to fit your index finger between the cuff and your arm easily, so you can pull the cuff off and on.
HEM-7080-C1_B_M.fm Page 20 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Taking a Reading The unit is designed to take measurements and store the measurement values in the memory for two people using user ID A and user ID B.
HEM-7080-C1_B_M.fm Page 21 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Selecting the User ID Select your user ID. Always use the same user ID when taking a measurement. The unit stores the measurement values in the memory by the user ID selected. These measurement values are used to calculate the morning averages and evening averages.
Page 22
HEM-7080-C1_B_M.fm Page 22 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Using the Single Mode Select your user ID (A or B). Press the START/STOP button. All symbols appear on the display. The user ID symbol you selected flashes on the display.
Page 23
HEM-7080-C1_B_M.fm Page 23 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Inflation stops automatically and the measurement is started. As the cuff deflates, decreasing numbers appear on the display. The heartbeat symbol ( ) flashes at every heartbeat.
Page 24
HEM-7080-C1_B_M.fm Page 24 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Selecting the Auto Mode Auto Mode may be selected for either A or B user. Make sure the unit is powered off. Select your user ID (A or B).
Page 25
HEM-7080-C1_B_M.fm Page 25 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Press the SET button to confirm the change. The number of seconds between each measurement is displayed. Note: The default value between each measurement is 60 seconds.
Page 26
HEM-7080-C1_B_M.fm Page 26 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Using the Auto Mode Select your user ID (A or B). Press the START/STOP button. All symbols appear on the display. The user ID Symbol you selected flashes on the display. The cuff starts to inflate automatically.
Page 27
HEM-7080-C1_B_M.fm Page 27 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit The second measurement is complete, waiting to start the next measurement. The third measurement starts automatically. The consecutive measurements are complete. The average for the three measurements appears on the display.
Page 28
HEM-7080-C1_B_M.fm Page 28 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Important: • If your systolic or diastolic pressure is outside the standard range, the heartbeat symbol will blink when the measurement result is displayed. Recent research suggests that the...
Page 29
HEM-7080-C1_B_M.fm Page 29 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit What is Irregular Heartbeat? An irregular Normal Heartbeat heartbeat is a Pulse heartbeat rhythm that varies by more Blood pressure than 25% from the average heartbeat Irregular Heartbeat...
HEM-7080-C1_B_M.fm Page 30 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Instructions for Special Conditions If your systolic pressure is known to be more than 220 mmHg, press and hold the START/STOP button until the arm cuff inflates 30 to 40 mmHg higher than your suspected systolic pressure.
HEM-7080-C1_B_M.fm Page 31 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Using the Memory Function The unit is designed to store the blood pressure and the pulse rate in the memory for two people (user A and user B) every time a measurement is completed.
HEM-7080-C1_B_M.fm Page 32 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Press the MEMORY button ( ) to display the most recent set of individual measurement values on the screen. The values are displayed from the most recent to the oldest.
HEM-7080-C1_B_M.fm Page 33 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Morning and Evening Averages The unit calculates and displays a weekly average for measurements taken in the morning ( ) and evening ( The unit stores 8 weeks of morning averages and 8 weeks of evening averages for each user (A and B).
Page 34
HEM-7080-C1_B_M.fm Page 34 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit About the Weekly Averages Morning Weekly Average This is the average for measurements taken during the morning (4:00 AM-9:59 AM) between Sunday and Saturday. An average for each day is calculated for up to three measurements taken within 10 minutes of the first measurement of the morning.
Page 35
HEM-7080-C1_B_M.fm Page 35 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit To Display Morning and Evening Averages Select your user ID (A or B). Press the morning average button ) or the evening average button The average for the current week “THIS...
Page 36
HEM-7080-C1_B_M.fm Page 36 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit Notes on Display Combinations In addition to the morning average and evening average symbols, the unit may also display the morning hypertension symbol if the morning average for that week is above the home blood pressure guideline.
HEM-7080-C1_B_M.fm Page 37 Tuesday, March 9, 2010 9:05 AM 3. Using the Unit The morning hypertension symbol ( ) appears if the weekly average for morning measurements is above 135/85. In this case the morning hypertension symbol ( ) is displayed when the evening average is displayed, regardless of the values for the evening average.
HEM-7080-C1_B_M.fm Page 38 Tuesday, March 9, 2010 9:05 AM 4. Quick Reference Guide This Quick Reference Guide is for reference only. Please read the entire manual before using the unit for the first time. To help ensure a reliable reading, avoid eating, smoking, or exercising for at least 30 minutes before taking a measurement.
HEM-7080-C1_B_M.fm Page 39 Tuesday, March 9, 2010 9:05 AM Care and maintenance 5. Handling Errors and Problems Error Messages Error Display Cause Remedy Cuff is under inflated. Carefully read and repeat Movement during the steps listed under measurement. Chapter 3.3 on page 20.
HEM-7080-C1_B_M.fm Page 40 Tuesday, March 9, 2010 9:05 AM 5. Handling Errors and Problems Troubleshooting Problem Cause Remedy No display appears when the START/ The batteries are empty. Replace the batteries. STOP button is pressed. Is the cuff wrapped Attach the arm cuff correctly around the correctly.
HEM-7080-C1_B_M.fm Page 41 Tuesday, March 9, 2010 9:05 AM 6. Maintenance and Storage To protect your unit from damage, please observe the following: • Do not subject your unit and cuff to extreme temperatures, humidity, moisture or direct sunlight. • Do not fold the cuff or tubing tightly.
HEM-7080-C1_B_M.fm Page 42 Tuesday, March 9, 2010 9:05 AM 7. Technical Data Product Description Digital Automatic Blood Pressure Monitor Model OMRON HEM-7080 Display LCD Digital Display Measurement Method Oscillometric method Measurement Range Pressure: 0 mmHg to 299 mmHg Pulse: 40 to 180/min.
Page 43
HEM-7080-C1_B_M.fm Page 43 Tuesday, March 9, 2010 9:05 AM 7. Technical Data • This device fulfils the provisions of EC directive 93/42/EEC (Medical Device Directive). • This blood pressure monitor is designed according to the European Standard EN1060, Noninvasive sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for electromechanical blood pressure measuring systems.
HEM-7080-C1_B_M.fm Page 44 Tuesday, March 9, 2010 9:05 AM 8. Some Useful Information about Blood Pressure What is Blood Pressure? Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the heart's cycle.
Page 45
HEM-7080-C1_B_M.fm Page 45 Tuesday, March 9, 2010 9:05 AM 8. Some Useful Information about Blood Pressure Upper curve: systolic blood pressure Lower curve: diastolic blood pressure Time of day Example: fluctuation within a day (male, 35 years old) Classification of Blood Pressure by the World...
1 . 概 要 主機 A. 顯示屏 F 用戶 ID 選擇開關 (A 與 B) B. SET(設置)按鈕 C. 日∕夜平均值 G. 電池倉 ( ∕ )按鈕 H. 空氣管接口 I. 交流適配器插孔(用於交 D. MEMORY(記憶)按鈕 流適配器) E. START/STOP(加壓∕ 停止)按鈕 臂帶 J. 臂帶(臂帶︰手臂週長 22-42 cm) K. 空氣插頭 L.
Page 51
1. 概要 顯示屏 M. 收縮壓 U 用戶 ID 符號(A 或 B) (表示使用者已選擇用戶 A N. 舒張壓 或用戶 B 進行測量或正在 O. 心律符號 使用記憶功能。) 1.(測量時閃爍) V. 脈搏顯示 2.(如果在測量完成後閃 爍,則表明血壓超出了正 W. 清晨高血壓符號 常值的範圍) (一週的清晨收縮壓平均讀 P. 移動符號 數超過 135 或舒張壓平均 (如測量時身體移動,則出現 讀數超過 85 時顯示。) 此符號。) X.
3. 血壓計的使用 3.3 讀數 本機可通過用戶 ID A 和 ID B 對兩位用戶進行測量並存儲其測 量值到記憶中。 還可使用訪客模式為其他人進行單次測量。使用訪客模式時 不會顯示用戶 ID 符號,該模式下測得的測量值也不會存儲在 記憶中。 使用訪客模式 按下 START/STOP(加壓∕停止)按鈕,直至 A 和 B 用戶符 號從顯示屏上消失。 A 和 B 顯示消失 按至少 3 秒鐘 鬆開 START/STOP(加壓∕停止)按鈕, 臂帶開始自動充氣。 注意: 要停止充氣,請按下並鬆開 START/ STOP(加壓∕ 停止)按鈕。血壓計將停止充氣,然後開始排氣並關 閉。...
Page 65
3. 血壓計的使用 選擇用戶 ID 選擇用戶 ID,並且每次測量請使用同一用戶 ID。這樣,血壓 計就可將測量值按所選擇的用戶 ID 存儲在記憶中。這些測量 值可用於計算清晨平均值和夜間平均值。 上下滑動用戶 ID 選擇開關,選擇用戶 A 或 B。 使用用戶 ID 選擇好用戶 ID 後,按下 START/STOP(加壓∕停止)按 鈕,可使用單次模式進行單次測量,也可使用自動模式連續 測量三次。 注意:血壓計已預設為單次模式進行單次測量。 使用自動模式可連續測量三次。該模式下,血壓計將自動對 臂帶充氣並進行三次測量。每兩次測量間會有短暫的時間間 隔。 7080_cs_new4.indd 21 7080_cs_new4.indd 21 3/30/07 11:15:35 3/30/07 11:15:35...
Need help?
Do you have a question about the HEM-7080 and is the answer not in the manual?
Questions and answers