Environmental
iX104C5 User's Handbook
Temperature
Humidity
Shock/Drop
Vibration
Enclosure Class
Appendix D. Hardware Specifications
• Operating:
o
o
o
-7
to 140
F (-20
to 60
o
F,-45
C)
• Storage:
o
o
o
-40
to 167
F (-40
to 75
0% to 95% non-condensing
Four-foot drop to concrete, all surfaces, edges and corners
0.04g^2/Hz, 20 Hz - 1000 Hz
-6dB/octave 1000 Hz - 2000 Hz
Blowing rain:
4"/hr, 40 mph wind and
MIL-STD-810G Method 506.5 Procedure 1
Ingress protection:
IEC (60529) ingress tested to an IP67 standard
Sand and dust:
Particle size < 149 µm, 10 + 7 g/m3 particle density 1.5 m/s
to 8.9 m/s wind speed
MIL-STD-810G Method 506.5 Procedure 1
Salt Fog:
5% saline for 48 hr (12 hr wet, 12 hr dry, 2 cycles)
MIL-STD-810G Method 506.5
Contamination by fluids:
Detergents, brake fluid, aromatic hydrocarbons
MIL-STD-810G Method 506.5
Solar radiation:
1120 W/m2 (355 Btu/ft2/hr) UVB @ 50° C, 7x24 hr cycles
MIL-STD-810G Method 506.5
o
C) (iX104C5M minimum is -49
o
C)