APW Wyott FD Installation And Operating Instructions Manual

Overhead warmers
Hide thumbs Also See for FD:

Advertisement

Quick Links

INSTALLATION
AND
OPERATING
INSTRUCTIONS
UNIT MUST BE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
!
liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
!
cause property damage, injury or death. Read the Installation, Operating and
Maintenance Instructions thoroughly before installing or servicing this equipment.
Initial heating of unit may generate smoke or fumes and must be done in a well ventilated area.
Overexposure to smoke or fumes may cause nausea or dizziness.
This equipment has been engineered to provide you with year-round dependable service when used
according to the instructions in this manual and standard commercial kitchen practices.
Phone:
(214) 421-7366
Fax:
(214) 565-0976
Toll Free: (800) 527-2100
Website: www.apwwyott.com
E-mail:
info@apwwyott.com
OVERHEAD WARMERS
INTENDED FOR OTHER THAN HOUSEHOLD USE
R
APW WYOTT 54" Food Warmer has been designed for use only on
4
the Metro
route stand. Each MetroR shelf has pre-drill holes to use
4
with APW WYOTT
wired cord and plug. Remote controls are factory pre-wired and only
have to be field mounted depending on route stand location. Follow
the "Installation Instructions" (in this booklet) to mount controls.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
Model:
mounting bracket. Each warmer ships with pre-
4
ANSI/NSF4
1
FD
P/N 70402030 2/06
APW / WYOTT
729 Third Avenue
Dallas, TX 75226
!
!

Advertisement

Table of Contents
loading

Summary of Contents for APW Wyott FD

  • Page 1 INTENDED FOR OTHER THAN HOUSEHOLD USE INSTALLATION OPERATING INSTRUCTIONS APW WYOTT 54” Food Warmer has been designed for use only on the Metro route stand. Each MetroR shelf has pre-drill holes to use with APW WYOTT mounting bracket. Each warmer ships with pre- wired cord and plug.
  • Page 2 IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or Parts, this information is required. Model Number Serial Number Date Purchased Notes:...
  • Page 3: Table Of Contents

    3. For best results, use stainless steel countertops. 4. All dimensions in parenthesis in centimeters unless noted. 5. APW Wyott Overhead Foodwarmers are constructed from high quality stainless steel and available in lengths from 18" to 72". Utilizing a metal sheath-heating element with a specially designed reflector, these units give uniform heat over the entire holding surface.
  • Page 4 Domino's Specific Installations on Metro® Route Stands: Remove food warmer and ceiling mounting brackets from packaging. Remove Ceiling s c r e w s f r o m e n d s o f Mounting food warmer; attach ceiling Bracket mounting bracket at both ends of food warmer (as shown).
  • Page 5 Use 88904 (screw), 89056 (washer), and 88921 (nut) to mount bracket. Place bracket (70402017) around shelving pole on the inner side of the shelving unit. Screw bracket (70402018) to bracket (70402017) around shelving pole on the outer side of the shelving unit. The bracket will allow the remote box inner side to align with the front side of the food warmer Bracket ( 7 0402017) Bracket...
  • Page 6: General Operation Instructions

    5. Never hold food below 150°F (66°C). Warranty Information: Reliability Backed By APW Wyott’s Warranty: All APW Wyott Holding Drawers are backed by a one year parts and labor warranty, including On-Site Service calls within 50 miles of authorized service technicians. Service Information: Service Hotline (800) 733-2203 2.
  • Page 7: Dimensions

    Do not use an extension cord with this appliance. Check with a qualified electrician if you are unsure as to whether the appliance is properly grounded. Overall Dimensions: FD MODELS .875 [ 2.22 ] CONDUIT HOLE POWER LEADS 6.000 [ 15.24 ] 4.104...
  • Page 8: Operation

    4. Check the rating label. Is the unit operating on proper voltage? B. If the above checks out, and problems still exist, call an APW Wyott authorized service agency. C. All service should be performed by an APW Wyott authorized service agency.
  • Page 9: Parts List & Exploded View

    7. FD PARTS LIST w/Exploded View ITEM # PART # DESCRIPTION DESCRIPTION ITEM # PART # 76841 HOUSING W/ASSY FD54 RH CTRL 70402017 BRACKET , FD REMOTE DOMINOS 89059 WASHER #10 EXTERNAL LOCK 55343 CONDUIT CONNECTOR, 90° FLEX 88961 NUT, HEX 10-24, GREEN 70402022 CONDUIT , 1/2"...
  • Page 10: Wiring Diagram

    8. FD18-72 WIRING DIAGRAMS REMOTE CONFIGURATION ELEMENT GREEN 120V: WHITE 200-240V: BLUE BROWN INFINITE CONTROL CONFIGURATION 120V: WHITE LABELS 200-240V: BLUE N/L2 BROWN ELEMENT GREEN PILOT LIGHT INFINITE CONTROL BROWN BLUE...
  • Page 11: Warranty

    APW Wyott's option or its Authorized Service Agency, it will be serviced on site or replaced. From day two through the conclusion of this warranty period, portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in-warranty repairs.
  • Page 12 Phone: (214) 421-7366 Fax: (214) 565-0976 APW WYOTT Toll Free: (800) 527-2100 729 Third Avenue Website: www.apwwyott.com E-mail: info@apwwyott.com Dallas, TX 75226...

Table of Contents