Page 1
INSTALLATION AND OPERATING INSTRUCTIONS FRY28, FRY30, & YDS5 DISHING STATIONS IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or Parts, this information is required. Model Number Serial Number...
THIS MANUAL SHOULD BE RETAINED FOR FUTURE REFERENCE Congratulations on your purchase of APW Wyott Modular Assembly Pack Station. APW Wyott takes pride in the design and quality of our products. When used as intended and with proper care and maintenance, you will experience years of reliable operation from this equipment.
NOTICE: If you have questions concerning the installation, operation, maintenance or service of this product, write Technical Service Department APW WYOTT Foodservice Equipment Company, P.O. Box 1829, Cheyenne, WY 82003. IMPORTANT: Check Store Layout for Placement and Location of MAPS2 System -Hot Table, Cold Table, Fries Table, and Toaster Table.
If you have questions concerning the installation, operation, maintenance or service of this product, Call: APW Wyott Technical Services Department 1-800-752-0863, ask for the Technical Service Department - Monday through Friday 9AM 6:30PM Eastern Time. STEP 1. POSITION TABLE...
Page 6
ELECTRICAL CONNECTIONS FOR FRY28 & FRY30 Check the data plate to determine what voltage this unit is wired for and what voltage service is to be used. SUPPLY REQUIREMENT: 80W/1920W, 120/208V, 15 Amp, 4 wire NOTE: Lights are 120V and power supplied for them is from line to neutral.
Page 7
DANGER: ELECTRICAL SHOCK CAN KILL. MAKE SURE POWER HAS BEEN DISCONNECTED AT THE SOURCE BEFORE MAKING THESE CONNECTIONS. WARNING: MAKE SURE THE CIRCUIT BREAKER HAS BEEN SIZED CORRECTLY FOR THIS APPLICATION. FRY28 Remove cover End covers can be for access to wires...
Page 8
ELECTRICAL CONNECTIONS FOR YDS5 Check the data plate to determine what voltage this unit is wired for and what voltage service is to be used. SUPPLY REQUIREMENT: 240 W/3800W, 120/208V, 30 Amp, 5 wire NOTE: Lights are 120V and power supplied for them is from line to neutral. YDS5 WIRING DIAGRAM...
Page 9
YDS5 WIRING SCHEMATIC INCANDESCENT LIGHTS NEUTRAL PILOT PILOT LIGHT LIGHT OVERHEAD OVERHEAD PWR SWITCH HEATER HEATER PILOT PILOT INIFINITE SWITCH LIGHT LIGHT PWR SWITCH 760 W 760 W 208 V 208 V OVERHEAD OVERHEAD HEATER HEATER PILOT PILOT INIFINITE SWITCH LIGHT LIGHT PWR SWITCH...
YDS5 Covers can be removed to run wires from one table to another Remove cover for access to wires Blue #45 Remove plug as needed for wire routing. Install wires Neutral and grommet. Field to determine proper wire routing. Brown #46 Power Source L1 Green w/Yellow Brown #47...
Page 11
MAINTENANCE: Never clean any electrical unit by immersing it in water. Turn unit off before cleaning surface. STAINLESS STEEL: To remove normal dirt or product residue from stainless steel, use ordinary soap and water with or without detergent applied with a sponge or cloth. Dry thoroughly with a clean cloth. Never use corrosive cleaner.
Page 12
YDS5 OPERATING INSTRUCTIONS Apply power to the unit. Turn on the red power switch to the far left of the control panel to turn on the lights. The light will illuminate indicating there is power to the unit. Turn on the next red power switch to turn on the first set of overhead heaters.
Page 13
Poor air supply Airflow is restricted through compressor compartment or the air is too hot. Remove restriction or source of heat. Leak (low on refrigerant) Call APW Wyott certified refrigeration technician. No power Make sure the power switch is on. Condensing...
If all of the above are correct and the unit still does not work, call an APW Wyott Authorized Service Agency. NOTICE: Only a qualified technician who is experienced in and knowledgeable with the operation of this electrical and refrigerated equipment should perform service work. Contact the Authorized Service Agency for reliable service, dependable advise or other assistance and for genuine factory parts.
APW Wyott's option or its Authorized Service Agency, it will be serviced on site or replaced. From day two through the conclusion of this warranty period, portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in-warranty repairs.