APW Wyott FRY28 Installation And Operating Instructions Manual

Dishing stations

Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS
FRY28, FRY30, & YDS5
Please complete this information and retain this manual for the life of the equipment. For
Warranty Service and/or Parts, this information is required.
Model Number
WARNING: Improper installation, operation, service or maintenance can cause
!
property damage, injury or death. Utility location is CRITICAL. Read and understand
these instructions thoroughly before positioning, installing, maintaining or servicing
this equipment.
APW WYOTT Foodservice Equipment Company
+1 (307) 634-5801 Phone
+1 (307) 637-8071 Fax
DISHING STATIONS
IMPORTANT FOR FUTURE REFERENCE
Serial Number
P.O. Box 1829
Cheyenne, WY 82003
R
1
Date Purchased
P/N 8806302 9/05
+1 (800) 752-0863 Toll Free
www.apwwyott.com
!

Advertisement

Table of Contents
loading

Summary of Contents for APW Wyott FRY28

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS FRY28, FRY30, & YDS5 DISHING STATIONS IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or Parts, this information is required. Model Number Serial Number...
  • Page 2: General Information

    THIS MANUAL SHOULD BE RETAINED FOR FUTURE REFERENCE Congratulations on your purchase of APW Wyott Modular Assembly Pack Station. APW Wyott takes pride in the design and quality of our products. When used as intended and with proper care and maintenance, you will experience years of reliable operation from this equipment.
  • Page 3: Table Of Contents

    Therefore, installation should comply with all local codes. TABLE OF CONTENTS ITEM SECTION PAGE General Information Safety Precautions Installation Check List Installation Utilities, Electrical & Plumbing Electrical Connections Operation & Maintenance Initial Cleaning Cleaning Maintenance Troubleshooting Chart Specifications Parts Lists & Exploded Views FRY28 FRY30 YDS5 Warranty...
  • Page 4: Installation Check List

    NOTICE: If you have questions concerning the installation, operation, maintenance or service of this product, write Technical Service Department APW WYOTT Foodservice Equipment Company, P.O. Box 1829, Cheyenne, WY 82003. IMPORTANT: Check Store Layout for Placement and Location of MAPS2 System -Hot Table, Cold Table, Fries Table, and Toaster Table.
  • Page 5: Installation

    If you have questions concerning the installation, operation, maintenance or service of this product, Call: APW Wyott Technical Services Department 1-800-752-0863, ask for the Technical Service Department - Monday through Friday 9AM 6:30PM Eastern Time. STEP 1. POSITION TABLE...
  • Page 6 ELECTRICAL CONNECTIONS FOR FRY28 & FRY30 Check the data plate to determine what voltage this unit is wired for and what voltage service is to be used. SUPPLY REQUIREMENT: 80W/1920W, 120/208V, 15 Amp, 4 wire NOTE: Lights are 120V and power supplied for them is from line to neutral.
  • Page 7 DANGER: ELECTRICAL SHOCK CAN KILL. MAKE SURE POWER HAS BEEN DISCONNECTED AT THE SOURCE BEFORE MAKING THESE CONNECTIONS. WARNING: MAKE SURE THE CIRCUIT BREAKER HAS BEEN SIZED CORRECTLY FOR THIS APPLICATION. FRY28 Remove cover End covers can be for access to wires...
  • Page 8 ELECTRICAL CONNECTIONS FOR YDS5 Check the data plate to determine what voltage this unit is wired for and what voltage service is to be used. SUPPLY REQUIREMENT: 240 W/3800W, 120/208V, 30 Amp, 5 wire NOTE: Lights are 120V and power supplied for them is from line to neutral. YDS5 WIRING DIAGRAM...
  • Page 9 YDS5 WIRING SCHEMATIC INCANDESCENT LIGHTS NEUTRAL PILOT PILOT LIGHT LIGHT OVERHEAD OVERHEAD PWR SWITCH HEATER HEATER PILOT PILOT INIFINITE SWITCH LIGHT LIGHT PWR SWITCH 760 W 760 W 208 V 208 V OVERHEAD OVERHEAD HEATER HEATER PILOT PILOT INIFINITE SWITCH LIGHT LIGHT PWR SWITCH...
  • Page 10: Operation & Maintenance

    YDS5 Covers can be removed to run wires from one table to another Remove cover for access to wires Blue #45 Remove plug as needed for wire routing. Install wires Neutral and grommet. Field to determine proper wire routing. Brown #46 Power Source L1 Green w/Yellow Brown #47...
  • Page 11 MAINTENANCE: Never clean any electrical unit by immersing it in water. Turn unit off before cleaning surface. STAINLESS STEEL: To remove normal dirt or product residue from stainless steel, use ordinary soap and water with or without detergent applied with a sponge or cloth. Dry thoroughly with a clean cloth. Never use corrosive cleaner.
  • Page 12 YDS5 OPERATING INSTRUCTIONS Apply power to the unit. Turn on the red power switch to the far left of the control panel to turn on the lights. The light will illuminate indicating there is power to the unit. Turn on the next red power switch to turn on the first set of overhead heaters.
  • Page 13 Poor air supply Airflow is restricted through compressor compartment or the air is too hot. Remove restriction or source of heat. Leak (low on refrigerant) Call APW Wyott certified refrigeration technician. No power Make sure the power switch is on. Condensing...
  • Page 14: Specifications

    If all of the above are correct and the unit still does not work, call an APW Wyott Authorized Service Agency. NOTICE: Only a qualified technician who is experienced in and knowledgeable with the operation of this electrical and refrigerated equipment should perform service work. Contact the Authorized Service Agency for reliable service, dependable advise or other assistance and for genuine factory parts.
  • Page 15 FRY30 30.656 30.656 56.188 56.188 WIRING CHANNEL WIRI NG CHANNEL DATA PLATE LOCATION DATA PLATE LOCATION 13.562 13.654 28.972 13.654 28.972 13.562 30.656 30.656 60.122 60.122 35.998 35.998 27.216 TYP. 27.216 TYP. 27.375 27.375 30.375 30.375 56.000 56.000 DIMENSIONS ELECTRICAL MODEL WEIGHT CUBE F.O.B.
  • Page 16 YDS5 60.000 60.000 11.688 11.688 29.125 29.125 11.688 11.688 ELECTRICAL CONDUIT WIRING CHANNEL DATA PLATE LOCATION 52.500 52.500 60.000 11.688 29.125 11.688 60.000 11.688 11.688 29.125 56.772 56.772 12.978 12.978 .875 .875 55.304 55.304 35.998 35.998 11.500 11.500 56.844 56.844 59.844 59.844 DIMENSIONS...
  • Page 17: Parts Lists & Exploded Views

    6. PARTS LISTS & EXPLODED VIEWS FRY 28 PARTS LIST & EXPLODED VIEW 21 22 ITEM DESCRIPTION ITEM DESCRIPTION 48711-10 Weldm't, Frame 15155-00 Light, Indicator 250V 48711-01 Top, Fry 28 13062-00 Switch, Rocker 250VAC 10A 48711-16 Pan, Potato Bed 13282-00 Switch, Infinite 48711-04 Label, Bottom Switch...
  • Page 18 FRY 30 PARTS LIST & EXPLODED VIEW ITEM DESCRIPTION ITEM DESCRIPTION 48731-23 Panel, Lower Enclosure 85053-00 Flat Washer 3/16 81349-00 8-32 X 3/8 Tr Hd 89784-00 Bushing, 7/8 Snap Hyco 81300-00 8-32 X 3/8 Type T 14319-10 Element, 208V, 760W 48731-21 Panel, OVS Left Side 82055-00...
  • Page 19 YDS5 PARTS LIST & EXPLODED VIEW ITEM ITEM DESCRIPTION DESCRIPTION 48728-10 Weldment, Frame 81730-00 Weldstud, 10-32 x .5 Lg. 48728-01 Top, Dishing Station 85053-00 Flat Washer 3/16 48728-16 Pan, Potato Bed Nut, Hex KEPS 10-32 8417100 48710-03 8-32 x 3/8 Type T Angle, Wire Channel 8130000 48728-26...
  • Page 20: Warranty

    APW Wyott's option or its Authorized Service Agency, it will be serviced on site or replaced. From day two through the conclusion of this warranty period, portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in-warranty repairs.