1.2
S
ETUP
Read the Operation Manual before setting up the Life Fitness Treadmill. Place the treadmill where it will be used before begin-
ning the setup procedure.
E
P
LECTRICAL
OWER
The Life Fitness Treadmill requires a dedicated* line according to the electrical configurations listed in the chart below.
* One individual branch circuit for each treadmill per NEC article 210-21 (b) (1) and 210-23 (or other appropriate, country specific electrical compliance
guidelines). The hot and neutral wires must each be routed independently (not looped or tied to other circuits.)" .
NOTE: Do not modify the plug provided with this product. If the plug does not fit into an available electrical outlet, have a prop-
er outlet installed by a qualified electrician.
G
I
ROUNDING
NSTRUCTIONS
This Life Fitness product must be properly grounded. If the unit malfunctions or breaks down, proper grounding provides a path
of least resistance for the electric current, which reduces the risk of shock to anyone touching or using the equipment. Each
unit is equipped with an electrical cord, which includes an equipment grounding conductor and a grounding plug. The plug
must be inserted into an outlet that has been properly installed and grounded in accordance with all local codes and ordi-
nances.
A temporary adapter MUST NOT BE USED to connect this plug to a two-pole receptacle in North America. If a
properly grounded, 20-amp outlet is not available, one must be installed by a qualified electrician. Models drawing
16 amps or more must be installed on a dedicated line.
IL EST ABSOLUMENT INTERDIT d'employer un adaptateur temporaire pour brancher cette fiche sur une prise
bipolaire en Amérique du Nord. Si aucune prise de 20 A correctement mise à la terre n'est disponible, en faire
installer une par un électricien qualifié. Les modèles utilisant 16 A ou plus doivent être branchés sur un circuit
spécialisé.
DANGER:
A risk of electrical shock may result from improper connection of the equipment-grounding
conductor. Check with a qualified electrician if in doubt as to proper grounding technique. DO NOT modify the
plug provided with the product. If it will not fit an electrical outlet, have a proper outlet installed by a qualified
electrician. Any modification to the electrical plug will result in a voided warranty.
Un branchement incorrect du conducteur de mise à la terre peut entraîner des risques de décharge électrique.
Consulter un électricien si des doutes subsistent quant à la technique de mise à la terre. NE PAS MODIFIER la fiche
fournie avec l'appareil. Si elle ne s'adapte pas à une prise, faire installer une prise correcte par un électricien qualifié.
Toute modification à la fiche annule la garantie.
H
P
OW TO
OSITION AND
Following all safety instructions in Section 1.1, move the treadmill to the location in
which it will be used. See Section 7, titled Specifications, for the dimensions of the
footprint. Allow a distance of eight inches, or 21 centimeters, between the treadmill and
other units on either side. Allow a distance of six feet, or two meters, from the rear of
the treadmill to any object or surface.
After placing the unit where it will be used, check its stability. If there is even a
slight rocking motion or the unit is not stable, determine which stabilizing leg is not
resting on the floor. To adjust, loosen the JAM NUT (A), and turn the STABILIZING
LEG (B) until the rocking motion ceases, and both stabilizing legs rest firmly on the floor. Retighten the JAM NUT.
NOTE: It is extremely important that the stabilizing leg be correctly adjusted for proper operation. An unbalanced unit may
cause striding belt misalignment. A bubble level is recommended to ensure proper leveling.
R
EQUIREMENTS
S
L
TABILIZE THE
IFE
F
T
ITNESS
READMILL
9