Summer/Winter
Button
Domestic Hot Water
Light - Green
Flame Failure
Light - Red
Burner ON
Light - Green
ON
Mains ON
Light - Green
Fig. 4
Domestic Hot Water
Temperature Control
Reset
High
Button
Low
Reset
High
Low
Central Heating
Maximum Radiator
Temperature Control

4.0 Safety Devices

4.1
Operation of Safety Devices
1. Your Baxi Combi HE Plus Range is fitted with safety
devices which shut down the appliance if:
a) the system overheats.
b) the condensate drain is blocked.
c) there is no gas to the boiler.
2. The flame failure light (
) will be either flashing or
permanently illuminated and the boiler will need resetting
(Fig. 4).
NOTE: In the case of persistent operation of the
devices, turn off the boiler and consult your service
engineer as an appliance or system fault is indicated.
4.2
Resetting (Fig. 4)
1. Check that the gas, water and electricity supplies to the
appliance have not been inadvertantly turned off.
2. Check the condensate drain outlet has not been
blocked.
WARNING: The condensate outlet must not
be blocked or modified.
3. Allow the boiler to cool if hot.
4. Hinge down the lower door panel.
5. Press the Reset Button.