Operation without heat pump

Transport

Unpacking

Standard delivery

Basement heating for summer period
Temperature limiter valve for domestic water
Safety valve hot tap water
Non-return valve
Sanyo CO2 Eco can be started without the heat pump being installed.
The product works then like a common electric boiler with full function of the
regulation. Make sure the heat pump is blocked in the control system, see User Manual.
To avoid transport damages, do not unpack the boiler until it has been
transported to its installation site in the boiler room. The boiler can be handled
and lifted in the following way:
truck
sleeve can be found on top of the boiler in the centre under the
insulation).
nd the pallet. Note! Only with the wrapping on.
To avoid damages by handling, unpack the boiler first when it is located in
its installation place. After the unpacking check:
s not been damaged during transport. Report eventual
damages to the forwarding agent.
the delivery is complete, see below.
co, including load circulation pump between tank unit and heat pump.
d bag with:
room sensor
primary flow sensor
outdoor sensor
installation and maintenance instruction
safety valve for domestic hot water, 9 bar
current sensors, 3 pcs
The boiler can be programm
heating, e.g. in the basement or in the log house, is desired during the
summer to avoid raw and damp air. Unde
OUT (=min. allowed flow temp) can be selected.
temperature does not go below the set value, even if the room sensor or
the heating curve desires a lower temperature.
The function demands that radiator thermostats or shut-off valves
are mounted in the other parts of the house.
This function can also be used for floor heating installed in e.g. a bathroom.
A temperature limiter valve for the domestic water must be mounted on the hot water tap to
avoid the risk of scalding.
Mount the enclosed valve to the incoming cold water connection. The waste
pipe must be connected to the drain gutter directly, or if the distance is
more than 2 m, to the waste funnel. The waste pipe must lean toward the
drain gutter.
Mount a non-return valve at the incoming domestic cold water connection.
ve on top of the boiler (extra
ntrol system make sure that the flow
basic