1
System Configuration....................................................................................................... 3
2
External Devices Selection .............................................................................................. 9
3
Communication Settings ................................................................................................ 10
4
Setup Items .................................................................................................................... 58
5
Cable Diagrams ............................................................................................................. 62
6
Supported Devices....................................................................................................... 139
7
Device Code and Address Code.................................................................................. 149
8
Error Messages............................................................................................................ 150
Mitsubishi Electric Corporation
1

Advertisement

loading

Summary of Contents for Mitsubishi Electric FREQROL

  • Page 1: Table Of Contents

    Mitsubishi Electric Corporation FREQROL Inverter Driver System Configuration....................... 3 External Devices Selection ....................9 Communication Settings ....................10 Setup Items ........................58 Cable Diagrams ......................62 Supported Devices....................... 139 Device Code and Address Code.................. 149 Error Messages......................150...
  • Page 2 FREQROL Inverter Driver Introduction This manual describes how to connect the Display and the External Device (target PLC). In this manual, the connection procedure is described in the sections identified below: System Configuration "1 System Configuration" (page 3) This section lists the types of External Devices and SIO that you can connect.
  • Page 3: System Configuration

    FREQROL Inverter Driver System Configuration The following table lists system configurations for connecting Mitsubishi Electric Corporation External Devices and the Display. • If problems such as communication interruptions due to a disconnection of the signal wire or malfunction of the Display cannot be detected on the inverter side, implement a precautionary measure by using the inverter’s communication retry function or...
  • Page 4 FREQROL Inverter Driver Series Inverter Link I/F SIO Type Setting Example Cable Diagram PU connector on RS-422/485 "Setting Example 9" " Cable Diagram 4" the Inverter (4 wire ) (page 26) (page 81) FR-V520L- K FR-V500L FR-V540L- K Terminal on RS-422/485 "Setting Example...
  • Page 5 FREQROL Inverter Driver Series Inverter Link I/F SIO Type Setting Example Cable Diagram PU connector on RS-422/485 "Setting Example " Cable Diagram 1" the Inverter (4 wire ) 22" (page 52) (page 62) FR-B- K RS-422/485 "Setting Example " Cable Diagram 2"...
  • Page 6 FREQROL Inverter Driver Connection Configuration • 1:1 Connection External Device Display • 1:n Connection External Device External Device External Device Display Maximum number of External Devices: 16 External Device External Device External Device Maximum number of External Devices: 32 Display...
  • Page 7 FREQROL Inverter Driver IPC COM Port When connecting IPC with an External Device, the COM port used depends on the series and SIO type. Please refer to the IPC manual for details. Usable port Usable Port Series RS-232C RS-422/485(4 wire)
  • Page 8 FREQROL Inverter Driver DIP Switch setting: RS-422/485 (4 wire) DIP Switch Setting Description Reserved (always OFF) SIO type: RS-422/485 Output mode of SD (TXD) data: Always output Terminal resistance (220Ω) insertion to SD (TXD): None Terminal resistance (220Ω) insertion to RD (RXD): None...
  • Page 9: External Devices Selection

    Select the External Device to be connected to the Display. Setup Items Setup Description Select the maker of the External Device to be connected. Select "Mitsubishi Electric Maker Corporation". Select a model (series) of the External Device to be connected and connection method.
  • Page 10: Communication Settings

    FREQROL Inverter Driver Communication Settings This section provides examples of communication settings recommended by Pro-face for the Display and the External Device. Setting Example 1 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC].
  • Page 11 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 12 FREQROL Inverter Driver Setting Example 2 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 13 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 14 FREQROL Inverter Driver Setting Example 3 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 15 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 16 FREQROL Inverter Driver Setting Example 4 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 17 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 18 FREQROL Inverter Driver Setting Example 5 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 19 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 20 FREQROL Inverter Driver Setting Example 6 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 21 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 22 FREQROL Inverter Driver Setting Example 7 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 23 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 24 FREQROL Inverter Driver Setting Example 8 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 25 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 26 FREQROL Inverter Driver Setting Example 9 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 27 FREQROL Inverter Driver External Device Settings Use the MODE key, SET key, up key, and down key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Press MODE key to select the parameter setting mode.
  • Page 28 FREQROL Inverter Driver 3.10 Setting Example 10 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 29 FREQROL Inverter Driver External Device Settings Use the MODE key, SET key, up key, and down key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Press MODE key to select the parameter setting mode.
  • Page 30 FREQROL Inverter Driver 3.11 Setting Example 11 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 31 FREQROL Inverter Driver External Device Settings Use the MODE key, SET key, up key, and down key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Press MODE key to select the parameter setting mode.
  • Page 32 FREQROL Inverter Driver 3.12 Setting Example 12 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 33 FREQROL Inverter Driver External Device Settings Use the MODE key, SET key, up key, and down key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Press MODE key to select the parameter setting mode.
  • Page 34 FREQROL Inverter Driver 3.13 Setting Example 13 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 35 FREQROL Inverter Driver External Device Settings Use the MODE key, SET key, up key, and down key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Press MODE key to select the parameter setting mode.
  • Page 36 FREQROL Inverter Driver 3.14 Setting Example 14 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 37 FREQROL Inverter Driver External Device Settings Use the MODE key, SET key, up key, and down key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Press MODE key to select the parameter setting mode.
  • Page 38 FREQROL Inverter Driver 3.15 Setting Example 15 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 39 FREQROL Inverter Driver External Device Settings Use the MODE key, SET key, up key, and down key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Press MODE key to select the parameter setting mode.
  • Page 40 FREQROL Inverter Driver 3.16 Setting Example 16 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 41 FREQROL Inverter Driver External Device Settings Use the PU/EXT key in the operation panel of the CPU unit and inverter setup software by Mitsubishi Electric Corporation for External Device communication settings. Refer to your External Device manual for details. Press PU/EXT key to select the PU operation mode.
  • Page 42 FREQROL Inverter Driver 3.17 Setting Example 17 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 43 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 44 FREQROL Inverter Driver 3.18 Setting Example 18 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 45 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 46 FREQROL Inverter Driver 3.19 Setting Example 19 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 47 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 48 FREQROL Inverter Driver 3.20 Setting Example 20 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 49 FREQROL Inverter Driver External Device Settings Use the MODE key, SET key, up key, and down key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Press MODE key to select the parameter setting mode.
  • Page 50 FREQROL Inverter Driver 3.21 Setting Example 21 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 51 FREQROL Inverter Driver External Device Settings Use the MODE key, SET key, up key, and down key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Press MODE key to select the parameter setting mode.
  • Page 52 FREQROL Inverter Driver 3.22 Setting Example 22 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 53 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 54 FREQROL Inverter Driver 3.23 Setting Example 23 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 55 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 56 FREQROL Inverter Driver 3.24 Setting Example 24 GP Pro-EX Settings Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC]. Device Setting To display the [Individual Device Settings] dialog box, select the external device and click [Settings] from [Device-Specific Settings] in the [Device/PLC] window.
  • Page 57 FREQROL Inverter Driver External Device Settings Use the PU/EXT key, MODE key, M dial and SET key in the operation panel of the CPU unit for External Device communication settings. Refer to your External Device manual for details. Turn ON the power supply.
  • Page 58: Setup Items

    FREQROL Inverter Driver Setup Items Set up the Display’s communication settings in GP Pro-EX or in the Display’s offline mode. The setting of each parameter must match that of the External Device. "3 Communication Settings" (page 10) Setup Items in GP Pro-EX Communication Settings To display the setup screen, from the [System Settings] workspace, select [Device/PLC].
  • Page 59 FREQROL Inverter Driver Setup Items Setup Description Select the communication control method to prevent overflow of transmission and Flow Control reception data. Use an integer from 1 to 127 to enter the time (s) for which the Display waits for the Timeout response from the External Device.
  • Page 60 FREQROL Inverter Driver Setup Items in Offline Mode • Refer to the Maintenance/Troubleshooting guide for information on how to enter offline mode or about the operation. Maintenance/Troubleshooting Guide "Offline Mode" • The number of the setup items to be displayed for 1 page in the offline mode depends on the Display in use.
  • Page 61 FREQROL Inverter Driver Setup Items Setup Description Select the communication control method to prevent overflow of transmission and reception Flow Control data. Use an integer from 1 to 127 to enter the time (s) for which the Display waits for the Timeout (s) response from the External Device.
  • Page 62: Cable Diagrams

    FREQROL Inverter Driver Cable Diagrams The cable diagrams shown below may be different from cable diagrams recommended by Mitsubishi Electric Corporation. Please be assured there is no operational problem in applying the cable diagrams shown in this manual. • The FG pin of the External Device body must be D-class grounded. Please refer to the manual of the External Device for more details.
  • Page 63 FREQROL Inverter Driver Recommended cables and connectors Item Type Manufacturer 10BASE-T cable SGLPEV-T 0.5mmx4P Mitsubishi Electric Corporation RJ45 connector 5-554720-3 Tyco Electronics AMP K.K. Do not use pin number 2 or 8. External Device side Display side RJ45 connector Terminal Block...
  • Page 64 FREQROL Inverter Driver External Device side Display side RJ45 connector Terminal Block Signal name Signal name CA4-ADPONL-01 Display CA3-ADPTRM-01 User-created cable Display side D-Sub 9pin (plug) External Device side Signal name RJ45 connector Signal name TERMRX CA4-ADPONL-01 Display TERMTX Shell...
  • Page 65 FREQROL Inverter Driver Display side External Device side Terminal block RJ45 connector Signal name Signal name Display GP-Pro EX Device/PLC Connection Manual...
  • Page 66 FREQROL Inverter Driver Cable Diagram 2 Display Cable Notes (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 GP3000 (COM1) AGP-3302B (COM2) Terminal block conversion adapter by Pro-face (COM2) CA3-ADPTRM-01 LT (COM1) User-created cable User-created cable Online adapter by Pro-face...
  • Page 67 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA3-ADPCOM-01 Shield Display TERM Signal name SDA1 (TXD1+) SDB1 (TXD1-) RDA1 (RXD1+) CA3-ADPTRM-01 RDB1 (RXD1-) SG (GND) User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 68 FREQROL Inverter Driver • 1:1 Connection Display side External Device side D-Sub 9pin (socket) Terminal Block Termination Signal name resistance Shield Signal name 100Ω (1/2W) SDA1 (TXD1+) SDB1 (TXD1-) Display RDA1 (RXD1+) RDB1 (RXD1-) SG (GND) Shell • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 69 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA4-ADPONL-01 Shield Display TERM Signal name SDA1 (TXD1+) SDB1 (TXD1-) RDA1 (RXD1+) CA3-ADPTRM-01 RDB1 (RXD1-) SG (GND) User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 70 FREQROL Inverter Driver • 1:1 Connection Display side D-Sub 9pin (plug) External Device side Terminal Block Signal name Shield TERMRX Signal name CA4-ADPONL-01 SDA1 (TXD1+) Display SDB1 (TXD1-) RDA1 (RXD1+) RDB1 (RXD1-) SG (GND) TERMTX Shell User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 71 FREQROL Inverter Driver • 1:1 Connection Display side External Device side Terminal block Terminal Block Signal name Shield Termination Signal name resistance*1 SDA1 (TXD1+) SDB1 (TXD1-) Display RDA1 (RXD1+) RDB1 (RXD1-) SG (GND) • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 72 FREQROL Inverter Driver Cable Diagram 3 Display Cable Notes (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 GP3000 (COM1) Terminal block conversion adapter by Pro-face AGP-3302B (COM2) CA3-ADPTRM-01 (COM2) LT (COM1) User-created cable User-created cable Online adapter by Pro-face...
  • Page 73 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA3-ADPCOM-01 Shield Display TERM Signal name SDA1 (TXD1+) SDB1 (TXD1-) RDA1 (RXD1+) CA3-ADPTRM-01 RDB1 (RXD1-) SG (GND) User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 74 FREQROL Inverter Driver • 1:1 Connection Display side External Device side D-Sub 9pin (socket) Terminal Block Termination Signal name resistance Shield Signal name 100Ω (1/2W) SDA1 (TXD1+) SDB1 (TXD1-) RDA1 (RXD1+) Display RDB1 (RXD1-) SG (GND) Shell • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 75 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA4-ADPONL-01 Shield Display TERM Signal name SDA1 (TXD1+) SDB1 (TXD1-) RDA1 (RXD1+) CA3-ADPTRM-01 RDB1 (RXD1-) SG (GND) User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 76 FREQROL Inverter Driver • 1:1 Connection Display side D-Sub 9pin (plug) External Device side Terminal Block Signal name Shield TERMRX Signal name CA4-ADPONL-01 SDA1 (TXD1+) Display SDB1 (TXD1-) RDA1 (RXD1+) RDB1 (RXD1-) SG (GND) TERMTX Shell User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 77 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA3-ADPCOM-01 Shield Display TERM Signal name SDA1 (TXD1+) SDB1 (TXD1-) RDA1 (RXD1+) CA3-ADPTRM-01 RDB1 (RXD1-) SG (GND) User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 78 FREQROL Inverter Driver • 1:1 Connection Display side External Device side D-Sub 9pin (socket) Terminal Block Termination Signal name resistance Shield Signal name 100Ω (1/2W) DATA+ SDA1 (TXD1+) DATA- SDB1 (TXD1-) RDA1 (RXD1+) Display RDB1 (RXD1-) GND(SG) SG (GND) Shell •...
  • Page 79 FREQROL Inverter Driver • 1:1 Connection Display side External Device side Terminal block Terminal Block Signal name Shield Signal name Termination resistance*1 SDA1 (TXD1+) SDB1 (TXD1-) RDA1 (RXD1+) Display RDB1 (RXD1-) SG (GND) • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 80 FREQROL Inverter Driver • 1:1 Connection Display side External Device side D-Sub 9pin (plug) Terminal Block Termination Signal name resistance Shield Signal name 100Ω (1/2W) LINE(+) SDA1 (TXD1+) LINE(-) SDB1 (TXD1-) RDA1 (RXD1+) Display RDB1 (RXD1-) SG (GND) GND(SG) RS(RTS) Shell •...
  • Page 81 FREQROL Inverter Driver Cable Diagram 4 Display Cable Notes (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 GP3000 (COM1) AGP-3302B (COM2) Terminal block conversion adapter by Pro-face (COM2) CA3-ADPTRM-01 LT (COM1) User-created cable User-created cable Online adapter by Pro-face...
  • Page 82 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block Distributor side Signal name RJ45 connector CA3-ADPCOM-01 Signal Display TERM name Distributor side External Device side RJ45 connector RJ45 connector Signal Signal Distributor name name CA3-ADPTRM-01 (BMJ-8P) Signal name Termination...
  • Page 83 FREQROL Inverter Driver • 1:n Connection Display side Terminal Block Distributor side Signal name RJ45 connector CA3-ADPCOM-01 Signal Display TERM name External Device side Distributor side RJ45 connector RJ45 connector Signal Signal Distributor CA3-ADPTRM-01 name name (BMJ-8) Distributor side RJ45 connector...
  • Page 84 FREQROL Inverter Driver • 1:1 Connection Display side Distributor side D-Sub 9pin (socket) RJ45 connector Termination Signal resistance Signal name name 100Ω (1/4W) Distributor side Distributor side RJ45 connector RJ45 connector Distributor Signal Signal Display (BMJ-8P) name name Signal name...
  • Page 85 FREQROL Inverter Driver • 1:n Connection Display side Distributor side D-Sub 9pin (socket) RJ45 connector Termination Signal resistance Signal name name 100Ω (1/4W) Distributor side Distributor side RJ45 connector RJ45 connector Distributor Signal Signal Display (BMJ-8) name name Distributor side...
  • Page 86 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block Distributor side Signal name RJ45 connector CA4-ADPONL -01 Signal Display TERM name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8P) name name CA3-ADPTRM-01 Signal name...
  • Page 87 FREQROL Inverter Driver • 1:n Connection Display side Terminal Block Distributor side Signal name RJ45 connector CA4-ADPONL -01 Signal Display TERM name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8) name name CA3-ADPTRM-01 Distributor side...
  • Page 88 FREQROL Inverter Driver • 1:1 Connection Display side D-Sub 9pin (plug) Distributor side Signal name RJ45 connector CA4-ADPONL -01 Signal Display TERMRX name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8P) name name TERMTX Signal...
  • Page 89 FREQROL Inverter Driver • 1:n Connection Display side D-Sub 9pin (plug) Distributor side Signal name RJ45 connector CA4-ADPONL -01 Signal Display TERMRX name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8) name name TERMTX Distributor side...
  • Page 90 FREQROL Inverter Driver • 1:1 Connection Display side Distributor side Terminal block RJ45 connector Signal Termination Signal name name resistance*1 Distributor side Distributor side RJ45 connector RJ45 connector Distributor Signal Signal Display (BMJ-8P) name name Signal name Termination resistance FR-CB20 cable 100Ω...
  • Page 91 FREQROL Inverter Driver • 1:n Connection Display side Distributor side Terminal block RJ45 connector Signal Termination Signal name name resistance*1 Distributor side Distributor side RJ45 connector RJ45 connector Distributor Signal Signal Display (BMJ-8) name name Distributor side RJ45 connector Signal...
  • Page 92 FREQROL Inverter Driver Cable Diagram 5 Display Cable Notes (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 GP3000 (COM1) Terminal block conversion adapter by Pro-face AGP-3302B (COM2) CA3-ADPTRM-01 (COM2) LT (COM1) User-created cable User-created cable Online adapter by Pro-face...
  • Page 93 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block Distributor side Signal name RJ45 connector CA3-ADPCOM-01 Signal Display TERM name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8P) name name CA3-ADPTRM-01 Signal name Termination resistance 100Ω...
  • Page 94 FREQROL Inverter Driver • 1:n Connection Display side Terminal Block Distributor side Signal name RJ45 connector CA3-ADPCOM-01 Signal Display TERM name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8) name name CA3-ADPTRM-01 Distributor side RJ45 connector...
  • Page 95 FREQROL Inverter Driver • 1:1 Connection Display side Distributor side D-Sub 9pin (socket) RJ45 connector Termination Signal resistance Signal name name 100Ω (1/4W) Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal Display (BMJ-8P) name name Signal...
  • Page 96 FREQROL Inverter Driver • 1:n Connection Display side Distributor side D-Sub 9pin (socket) RJ45 connector Termination Signal resistance Signal name name 100Ω (1/4W) Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal Display (BMJ-8) name name Distributor side...
  • Page 97 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block Distributor side Signal name RJ45 connector CA4-ADPONL-01 Signal Display TERM name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8P) CA3-ADPTRM-01 name name Signal name Termination resistance 100Ω...
  • Page 98 FREQROL Inverter Driver • 1:n Connection Display side Terminal Block Distributor side Signal name RJ45 connector CA4-ADPONL-01 Signal Display TERM name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8) CA3-ADPTRM-01 name name Distributor side RJ45 connector...
  • Page 99 FREQROL Inverter Driver • 1:1 Connection Display side D-Sub 9pin (plug) Distributor side Signal name RJ45 connector CA4-ADPONL-01 Signal Display TERMRX name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8P) name name TERMTX Signal Shell...
  • Page 100 FREQROL Inverter Driver • 1:n Connection Display side D-Sub 9pin (plug) Distributor side Signal name RJ45 connector CA4-ADPONL-01 Signal Display TERMRX name Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8) name name TERMTX Distributor side...
  • Page 101 FREQROL Inverter Driver • 1:1 Connection Distributor side RJ45 connector Display side Signal Terminal Block name Signal name Distributor side External Device side CA3-ADPCOM-01 Display TERM RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8P) name name CA3-ADPTRM-01 Signal name Termination resistance 100Ω...
  • Page 102 FREQROL Inverter Driver • 1:n Connection Distributor side RJ45 connector Display side Signal Terminal Block name Signal name Distributor side External Device side CA3-ADPCOM-01 Display TERM RJ45 connector RJ45 connector Distributor Signal Signal (BMJ-8) name name CA3-ADPTRM-01 Distributor side RJ45 connector...
  • Page 103 FREQROL Inverter Driver • 1:1 Connection Distributor side RJ45 connector Signal name Display side D-Sub 9pin (socket) Termination Distributor side External Device side resistance Signal name RJ45 connector RJ45 connector Distributor 100Ω (1/4W) Signal Signal DATA+ (BMJ-8P) name name DATA-...
  • Page 104 FREQROL Inverter Driver • 1:n Connection Distributor side RJ45 connector Signal name Display side D-Sub 9pin (socket) Termination Distributor side External Device side resistance Signal name RJ45 connector RJ45 connector Distributor 100Ω (1/4W) Signal Signal DATA+ (BMJ-8) name name DATA-...
  • Page 105 FREQROL Inverter Driver • 1:1 Connection Display side Distributor side Terminal block RJ45 connector Signal Termination Signal name name resistance*1 Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal Display (BMJ-8P) name name Signal name Termination resistance 100Ω...
  • Page 106 FREQROL Inverter Driver • 1:n Connection Display side Distributor side Terminal block RJ45 connector Signal Signal name Termination name resistance*1 Distributor side External Device side RJ45 connector RJ45 connector Distributor Signal Signal Display (BMJ-8) name name Distributor side RJ45 connector...
  • Page 107 FREQROL Inverter Driver • 1:1 Connection Distributor side RJ45 connector Signal Display side name D-Sub 9pin (plug) Distributor side External Device side Termination resistance Signal name RJ45 connector RJ45 connector Distributor 100Ω (1/4W) Signal Signal LINE(+) (BMJ-8P) name name LINE(-)
  • Page 108 FREQROL Inverter Driver • 1:n Connection Distributor side RJ45 connector Signal name Display side D-Sub 9pin (plug) Termination Distributor side External Device side resistance Signal name RJ45 connector RJ45 connector Distributor 100Ω (1/4W) Signal Signal LINE(+) (BMJ-8) name name LINE(-)
  • Page 109 FREQROL Inverter Driver Cable Diagram 6 Display Cable Notes (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 GP3000 (COM1) Terminal block conversion adapter by Pro-face AGP-3302B (COM2) CA3-ADPTRM-01 (COM2) LT (COM1) User-created cable User-created cable Online adapter by Pro-face...
  • Page 110 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block Signal name Shield CA3-ADPCOM-01 Display TERM External Device side Terminal Block Termination Signal name resistance 100Ω (1/2W) CA3-ADPTRM-01 User-created cable • 1:n Connection Display side Terminal Block Signal name Shield...
  • Page 111 FREQROL Inverter Driver • 1:1 Connection Display side D-Sub 9pin (socket) Termination resistance Signal name Shield External Device side 100Ω (1/2W) Terminal Block Termination Signal name resistance 100Ω (1/2W) Display Shell • 1:n Connection Display side D-Sub 9pin (socket) Termination...
  • Page 112 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block Signal name Shield CA4-ADPONL-01 Display TERM External Device side Terminal Block Termination Signal name resistance 100Ω (1/2W) CA3-ADPTRM-01 User-created cable • 1:n Connection Display side Terminal Block Signal name Shield...
  • Page 113 FREQROL Inverter Driver • 1:1 Connection Display side D-Sub 9pin (plug) Signal name CA4-ADPONL-01 Shield Display TERMRX External Device side Terminal Block Termination Signal name resistance 100Ω (1/2W) TERMTX Shell User-created cable • 1:n Connection Display side D-Sub 9pin (plug)
  • Page 114 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Terminal Block Signal name Termination Shield CA3-ADPCOM-01 Signal name resistance Display TERM 100Ω (1/2W) CA3-ADPTRM-01 User-created cable • 1:n Connection Display side Terminal Block External Device side...
  • Page 115 FREQROL Inverter Driver • 1:1 Connection External Device side Display side Terminal Block D-Sub 9pin (socket) Termination Termination Shield resistance Signal name resistance Signal name 100Ω (1/2W) 100Ω (1/2W) DATA+ DATA- Display GND(SG) Shell • 1:n Connection External Device side...
  • Page 116 FREQROL Inverter Driver • 1:1 Connection Display side Terminal block Termination Shield Signal name External Device side resistance*1 Terminal Block Termination Signal name resistance 100Ω (1/2W) Display • 1:n Connection Display side Terminal block Termination Shield Signal name External Device side...
  • Page 117 FREQROL Inverter Driver • 1:1 Connection External Device side Display side Terminal Block D-Sub 9pin (plug) Termination Termination Shield resistance Signal name resistance Signal name 100Ω (1/2W) 100Ω (1/2W) LINE(+) LINE(-) Display GND(SG) RS(RTS) Shell • 1:n Connection External Device side...
  • Page 118 FREQROL Inverter Driver Cable Diagram 7 Display Cable Notes (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 GP3000 (COM1) AGP-3302B (COM2) Terminal block conversion adapter by Pro-face (COM2) CA3-ADPTRM-01 LT (COM1) User-created cable User-created cable Online adapter by Pro-face...
  • Page 119 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA3-ADPCOM-01 Shield Display Signal name TERM CA3-ADPTRM-01 User-created cable • 1:n Connection Display side Terminal Block External Device side External Device side Signal name...
  • Page 120 FREQROL Inverter Driver • 1:1 Connection External Device side Display side D-Sub 9pin (socket) Terminal Block Termination Shield resistance Signal name Signal name 100Ω (1/2W) Display Shell • 1:n Connection Display side External Device side External Device side Terminal Block...
  • Page 121 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA4-ADPONL-01 Shield Display Signal name TERM CA3-ADPTRM-01 User-created cable • 1:n Connection Display side Terminal Block External Device side External Device side Signal name...
  • Page 122 FREQROL Inverter Driver • 1:1 Connection Display side D-Sub 9pin (plug) External Device side Signal name Terminal Block CA4-ADPONL-01 Shield Display TERMRX Signal name TERMTX Shell User-created cable • 1:n Connection Display side D-Sub 9pin (plug) External Device side External Device side...
  • Page 123 FREQROL Inverter Driver • 1:1 Connection Display side External Device side Terminal block Terminal Block Shield Signal name Signal name Termination resistance*1 Display • 1:n Connection Display side External Device side External Device side Terminal block Terminal Block Terminal Block...
  • Page 124 FREQROL Inverter Driver Cable Diagram 8 Display Cable Notes (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 GP3000 (COM1) AGP-3302B (COM2) Terminal block conversion adapter by Pro-face (COM2) CA3-ADPTRM-01 LT (COM1) User-created cable User-created cable Online adapter by Pro-face...
  • Page 125 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA3-ADPCOM-01 Shield Display TERM Signal name CA3-ADPTRM-01 User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 126 FREQROL Inverter Driver • 1:1 Connection Display side External Device side D-Sub 9pin (socket) Terminal Block Termination Signal name resistance Shield Signal name 100Ω (1/2W) Display Shell • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 127 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA4-ADPONL-01 Shield Display Signal name TERM CA3-ADPTRM-01 User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 128 FREQROL Inverter Driver • 1:1 Connection Display side D-Sub 9pin (plug) External Device side Signal name Terminal Block Shield TERMRX Signal name CA4-ADPONL-01 Display TERMTX Shell User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 129 FREQROL Inverter Driver • 1:1 Connection Display side External Device side Terminal block Terminal Block Signal name Shield Signal name Termination resistance*1 Display • Please set the terminating resistor switch of the External Device to the "100Ω" position. • 1:n Connection...
  • Page 130 FREQROL Inverter Driver Cable Diagram 9 Display Cable Notes (Connection Port) COM port conversion adapter by Pro-face CA3-ADPCOM-01 GP3000 (COM1) Terminal block conversion adapter by Pro-face AGP-3302B (COM2) CA3-ADPTRM-01 (COM2) LT (COM1) User-created cable User-created cable Online adapter by Pro-face...
  • Page 131 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA3-ADPCOM-01 Shield Display Signal name TERM CA3-ADPTRM-01 User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 132 FREQROL Inverter Driver • 1:1 Connection Display side External Device side D-Sub 9pin (socket) Terminal Block Termination Signal name Shield resistance Signal name 100Ω (1/2W) Display Shell • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 133 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA4-ADPONL-01 Shield Display TERM Signal name CA3-ADPTRM-01 User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 134 FREQROL Inverter Driver • 1:1 Connection Display side D-Sub 9pin (plug) External Device side Signal name Terminal Block Shield TERMRX Signal name CA4-ADPONL-01 Display TERMTX Shell User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 135 FREQROL Inverter Driver • 1:1 Connection Display side Terminal Block External Device side Signal name Terminal Block CA3-ADPCOM-01 Shield Display Signal name TERM CA3-ADPTRM-01 User-created cable • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 136 FREQROL Inverter Driver • 1:1 Connection Display side External Device side D-Sub 9pin (socket) Terminal Block Termination Signal name resistance Shield Signal name 100Ω (1/2W) DATA+ DATA- Display GND(SG) Shell • Please set the terminating resistor switch of the External Device to the "100Ω" position.
  • Page 137 FREQROL Inverter Driver • 1:1 Connection Display side External Device side Terminal block Terminal Block Signal name Shield Signal name Termination resistance*1 Display • Please set the terminating resistor switch of the External Device to the "100Ω" position. • 1:n Connection...
  • Page 138 FREQROL Inverter Driver • 1:1 Connection Display side External Device side D-Sub 9pin (plug) Terminal Block Termination Signal name resistance Shield Signal name 100Ω (1/2W) LINE(+) LINE(-) Display GND(SG) RS(RTS) Shell • The 5V output (Pin #6) on the GP-4107 is the power for the Siemens AG’s PROFIBUS connector.
  • Page 139: Supported Devices

    FREQROL Inverter Driver Supported Devices The following table shows the range of supported device addresses. Please note that the actually supported range of the devices varies depending on the External Device to be used. Please check the actual range in the manual of your External Device.
  • Page 140 FREQROL Inverter Driver This address can be specified as system data area. Device Bit Address Word Address 32bits Notes 000.00 - 991.15 000 - 991 *2 *3 Parameter 000.00 - 993.15 000 - 993 *3 *5 Parameter P037.00 - P037.31...
  • Page 141 FREQROL Inverter Driver Setting Items List FR-E700 series, FR-E500 series, FR-S500 series, FR-F500J series Word FR-E700 series FR-E500 series FR-S500 series FR-F500J series Address Operation mode Operation mode Operation mode Operation mode S01/ Output frequency/speed Output frequency[speed] Output frequency[speed] Output frequency[speed]...
  • Page 142 FREQROL Inverter Driver Word FR-E700 series FR-E500 series FR-S500 series FR-F500J series Address Inverter thermal load factor Alarm definition Alarm definition Alarm definition Alarm definition (Latest Nos. 1&2) (Latest Nos. 1&2) (Latest Nos. 1&2) (Latest Nos. 1&2) Alarm definition Alarm definition...
  • Page 143 FREQROL Inverter Driver FR-A700/FR-A701 series, FR-F700 series, FR-B,B3(A700) series, FR-B,B3(A500) series Word FR-A700/FR-A701 series FR-F700 series FR-B,B3(A700) series FR-B,B3(A500) series Address Operation mode Operation mode Operation mode Operation mode Output frequency/speed Output frequency/speed Output frequency/speed Output frequency[speed] Output current Output current...
  • Page 144 FREQROL Inverter Driver Word FR-A700/FR-A701 series FR-F700 series FR-B,B3(A700) series FR-B,B3(A500) series Address Alarm definition Alarm definition Alarm definition Alarm definition (Latest Nos. 5&6) (Latest Nos. 5&6) (Latest Nos. 5&6) (Latest Nos. 5&6) Alarm definition Alarm definition Alarm definition Alarm definition (Latest Nos.
  • Page 145 FREQROL Inverter Driver FR-A500/FR-A500L series, FR-F500/FR-F500L series, FR-C500 series Word FR-A500/FR-A500L series FR-F500/FR-F500L series FR-C500 series Address Operation mode Operation mode Operation mode Output frequency[speed] Output frequency[speed] Output frequency[speed] Output current Output current Output current Output voltage Output voltage Special monitor...
  • Page 146 FREQROL Inverter Driver Word FR-A500/FR-A500L series FR-F500/FR-F500L series FR-C500 series Address Alarm definition Alarm definition (Latest Nos. 5&6) (Latest Nos. 5&6) Alarm definition Alarm definition (Latest Nos. 7&8) (Latest Nos. 7&8) Run command Run command Run command Inverter status monitor...
  • Page 147 FREQROL Inverter Driver FR-V500/FR-V500L series Word FR-V500/FR-V500L series Address SL00 Operation mode SL01 Speed SL02 Output current SL03 Output voltage SL04 Special monitor Special monitor selection SL05 SL06 Output frequency SL07 Output current SL08 Output voltage SL09 Speed setting SL10...
  • Page 148 FREQROL Inverter Driver Word FR-V500/FR-V500L series Address Alarm definition SL45 (Latest Nos. 5&6) Alarm definition SL46 (Latest Nos. 7&8) SL47 SL48 Run command SL49 SL50 Inverter status monitor SL51 Set speed read (RAM) SL52 Set speed read (EEPROM) SL53 Set speed write (RAM)
  • Page 149: Device Code And Address Code

    FREQROL Inverter Driver Device Code and Address Code Use device code and address code when you set "Device Type & Address" for the address type of the data display or other devices. Device Device Name Device Code (HEX) Address Code...
  • Page 150: Error Messages

    FREQROL Inverter Driver Error Messages Error messages are displayed on the Display screen as follows: "No. : Device Name: Error Message (Error Occurrence Area)". Each description is shown below. Item Description Error number Name of the External Device where an error has occurred. Device/PLC name is the title of Device Name the External Device set with GP Pro-EX.
  • Page 151 FREQROL Inverter Driver Error No. Error Message Description Displayed when the incorrect device is used. (Node Name): Please change to use When the External Device data length is 4- RHxx130 (Device Address) to read the Setting byte and 6-byte, use the S device and the Items/data.