Black & Decker MAXX SST Instruction Manual

Black & Decker MAXX SST Instruction Manual

1,000 watt compact power inverter
Hide thumbs Also See for MAXX SST:

Advertisement

MAXX SST
TM
1,000 WATT COMPACT POWER INVERTER

INSTRUCTION MANUAL

Catalog Number VEC049DCB
BEFORE RETURNING THIS PRODUCT
FOR ANY REASON PLEASE CALL
1-877-571-2391
BEFORE YOU CALL, HAVE THE CATALOG No
,
AVAILABLE
.
IN MOST CASES
,
A REPRESENTATIVE
CAN RESOLVE THE PROBLEM OVER THE PHONE.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
1

Advertisement

Table of Contents
loading

Summary of Contents for Black & Decker MAXX SST

  • Page 1: Instruction Manual

    MAXX SST 1,000 WATT COMPACT POWER INVERTER INSTRUCTION MANUAL Catalog Number VEC049DCB BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1-877-571-2391 BEFORE YOU CALL, HAVE THE CATALOG No AVAILABLE IN MOST CASES A REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE.
  • Page 2: Safety Guidelines - Definitions

    Minimum Gauge for Cord Sets SAFETY GUIDELINES / DEFINITIONS Volts Total Length of Cord in Feet 120V 0-25 26-50 51-100 101-150 (0-7,6m) (7,6-15,2m) (15,2-30,4m) (30,4-45,7m) DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. 240V 0-50 51-100...
  • Page 3: Principle Of Operation

    “Installation” and “Specifications” sections of this Instruction Manual. Permanent Installation must be MAXX SST™ uses a 12 volt DC power source like those found in motor vehicles, or it can be operated using performed by a professional as specified in the “Installation” section of this Instruction Manual.
  • Page 4: Appliance Power Consumption

    Also ensure that start-up wattage for inductive loads up. Because the MAXX SST™ inverters have a peak watt power rating, many such appliances and tools may be does not exceed peak watts for more than a second.
  • Page 5: Installation

    • NEVER place items on or over the inverter during operation. 100 10 • MAXX SST™ inverters generate heat during operation and must be placed where cool air can circulate to the 50 A/h internal fan, and hot air can be removed.
  • Page 6: Troubleshooting

    BATTERY Television Interference The Inverter is shielded to minimize interference with TV signals. However, in ANL FUSE some instances, some interference may still be visible, particularly with weak TV MAXX SST™ signals. Try the following corrective measures: POWER BATTERY INVERTER •...
  • Page 7: Care And Maintenance

    CARE AND MAINTENANCE SPECIFICATIONS Maximum continuous power: 1000 watt Storage 1.Ideal storage temperature range is 50-68°F (10-20°C). Surge capacity (peak power): 2000 watt 2.Store and use the inverter in a cool, dry place with adequate ventilation. a t l s t l 3.Avoid locations that are exposed to heating units, radiators, direct sunlight or excessive humidity or e r f : y c...

Table of Contents