3
Function setting
M-NET address
Function No.
Data
Function
Select:
Cursor
Function setting
M-NET address
Function No.
Data
Sending data
4
Function setting
M-NET address
Function No.
Data
Setting completed
Return:
The Function Setting screen will appear.
Press the F1 or F2 button to move the cursor
3
32
to one of the following: M-NET address, function
2
Set
/ Conf
setting number, or setting value. Then, press the
F3 or F4 button to change the settings to the
Address
desired settings.
Once the settings have been completed, press
the SELECT button.
A screen will appear that indicates that the
settings information is being sent.
3
32
2
When the settings information has been sent, a
screen will appear that indicates its completion.
3
32
2
To make additional settings, press the RETURN
button to return to the screen shown in Step 3
above. Set the function numbers for other indoor
units by following the same steps.
Navigating through the screens
• To return to the Service Menu screen .......... MENU button
• To return to the previous screen ...... RETURN button
To check the current settings of a given unit, enter
the setting for its M-NET address and function setting
number, select Conf for the Function, and press the
SELECT button.
A screen will appear that indicates that the settings
are being searched for. When the search is done, the
current settings will appear.
51