Disassembly For Repair; Removing The Torque Changeover Lever; Mounting The Torque Changeover Lever; Procedures When Replacing The Diode (1Sr139-400) For Hand Mounting - Kenwood TS-590S Service Manual

Hf / 50mhz all mode transceiver
Hide thumbs Also See for TS-590S:
Table of Contents

Advertisement

Removing the torque changeover lever

(G02-1858-03)
1. Insert the tip of a fl at-head screwdriver (or other imple-
ment) under the tab of the torque changeover lever, then
lift the tab using the tip of the fl at-head screwdriver. (q)
Caution: Be careful not to damage the panel when lifting
it.
2. Turn the lever section of the torque changeover lever to
the right, as in the position described in step 1. (w)
3. Lift the torque changeover lever and remove it from the
panel. (e)

DISASSEMBLY FOR REPAIR

Mounting the torque changeover lever

(G02-1858-03)
1. Insert the torque changeover lever by aligning the three
tabs of the panel. (q)
2. Slightly turn the lever section of the torque changeover
lever to the left (e) while pressing the surface near the
tab at the lower right of the torque changeover lever (w).
Caution: Confirm that the torque changeover lever is
caught by the lower right tab of the panel.
3. Turn the lever section of the torque changeover lever to
the left (t) while pressing the surface near the tab at
the upper right of the torque changeover lever (r), then
mount it onto the panel.
Procedures when Replacing the Diode
(1SR139-400) for hand mounting
1. When replacing the diode (D304: 1SR139-400) used by
the Control unit (A/3) (PCB number: J79-0279-09), cut
the leg of a new diode.
5mm
(0.2 inches)
Cathode band (Green)
TS-590S
2mm
(0.08 inches)
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents