Receiver Section - Kenwood TS-590S Service Manual

Hf / 50mhz all mode transceiver
Hide thumbs Also See for TS-590S:
Table of Contents

Advertisement

Receiver Section

Item
Condition
• Perform the following in the adjustment mode. Item 4 and 8~22.
To terminate the adjustment menu in the middle, save your settings with Menu No. 60.
1. Trap
1) Display f.: 15.501MHz
frequency
Mode: USB
(E type only)
PRE-AMP: ON
• 15.5MHz
• 11.7MHz
2) Display f.: 11.700MHz
Mode: USB
PRE-AMP: ON
2. HF BPF
1) Display f.: 7.200MHz
Mode: USB
PRE-AMP: ON
2) Display f.: 14.200MHz
Mode: USB
PRE-AMP: ON
3. IF Trap
1) Display f.: 50MHz
(73.095MHz)
Mode: USB
PRE-AMP: ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Tracking
Rear
ANT 1
TX-RX
generator
panel
(A/2)
Spectrum
TX-RX
CN201
analyzer
(A/2)
TS-590S
Adjustment
Parts
Method
TC102 Adjust TC102 to
get a null point
at 15.501MHz as
shown.
TC101 Adjust TC101 to
get a null point at
11.7MHz as shown.
Repeat the trap
frequency adjust-
ment 2 to 3 times,
alternating between
15.5MHz and
11.7MHz.
L133
Adjust the coils to
L150
obtain the frequency
6.9MHz 7.5MHz
L167
response as shown.
L134
K type
L153
13.9MHz 14.5MHz
L168
E type
13.9MHz 14.5MHz
L135
Adjust L135 at
73.095MHz to mini-
mum level.
Specifi cations / Remarks
15.501MHz
11.7MHz
73.095MHz
71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents