Service Information
7957 A/7958A
Oct
Dec
650
53
660
54
670
55
700
56
710
57
720
58
Hex
35
36
37
38
39
3A
Table 4-2. Error Codes (2 of 6)
Description
Marginal Sector Not Found error on a write operation.
Unrecoverable Sector Not Found error on a write operation.
Marginal No Data Sync error on a write operation.
Unrecoverable No Data Sync error on a write operation.
Marginal Sector Overrun error on a write operation.
Unrecoverable Sector Overrun error on a write operation.
Self test errors. A fault log entry will be generated. In the Request Status parameter bytes, P7 will
contain the fault code, P8 will contain the ESDI status, P9 will contain the least significent byte (LSByte)
of Vendor Unique Status.
1010
65
41
Buffer RAM test failed.
1020
66
42
Self test data compare failed.
1030
67
43
Self test R/W retry count exhausted.
1040
68
44
ECC test failed.
1050
69
45
Drive selected line not asserted during power on.
1060
70
46
Timeout 30 seconds waiting for Command Complete during power
on.
1070
71
47
Illegal ESDI status during power on.
1100
72
48
Drive Ready not asserted after Command Complete during power
on.
1110
73
49
Auto configuration failed; probably ESDI communication problem
(no configuration parameters checked).
1130
75
4B
Reset attention failed during power on.
1140
76
4C
Vendor unique status available.
1150
77
4D
Mechanism self test has failed.
1160
78
4E
One of the four seek diagnostic tests failed (ATN, ESDI comm,
verify failed twice).
Controller Faults. A fault log entry will be generated. In the Request Status parameter bytes, P7 will
contain the! fault code.
1220
1230
1240
1250
82
83
84
85
52
53
54
55
FIFO data loss retry on a read operation failed.
FIFO Data Loss Retry on a write operation failed.
Offset recovery position unknown.
Seek recovery position unknown.
COMPRESSED ESDI STATUS
o
=
WI~
i te fau 1 t
1
=
2
=
3
4
5
=
6
=
7
=
write gate with track offset fault
seek fault
invalid/unimplemented command fault
interface fault
command data parity fault
PON conditions exist/start spindle motor command may be required
spindle motor stopped
4-41