Blaze King 6003 Installation And Operating Instructions Manual

Contemporary freestanding direct vent heater

Advertisement

CONTEMPORARY FREESTANDING DIRECT VENT HEATER
Dealer:
Installer:
Phone:
Installation Date:
Serial Number:
INSTALLER: PLEASE LEAVE THIS MANUAL WITH THE CUSTOMER
CUSTOMER: PLEASE KEEP MANUAL FOR FUTURE REFERENCE
WARNING: If the information in these instructions are not followed exactly, a fire or explosion
may result casing property damage, personal injury may result.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
MANUFACTURED IN CANADA BY:
Valley Comfort Systems Inc.
1290 Commercial Way
Penticton, BC V2A 3H5
Ph# 1-250-493-7444
Email sales@blazeking.com
Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com
OM6003.PUB
Blaze King
QUALITY HEARTH PRODUCTS

INSTALLATION AND OPERATING INSTRUCTIONS

CERTIFIED FOR CANADA AND USA
MODEL 6003
Page 1
MANUFACTURED IN USA BY:
Blaze King Industries
146 A Street
Walla Walla, WA. 99362
Ph# 1-509-522-2730
Email ussales@blazeking.com
DATE PRINTED: 4/7/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6003 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Blaze King 6003

  • Page 1: Installation And Operating Instructions

    Blaze King QUALITY HEARTH PRODUCTS INSTALLATION AND OPERATING INSTRUCTIONS CONTEMPORARY FREESTANDING DIRECT VENT HEATER MODEL 6003 Dealer: Installer: Phone: Installation Date: Serial Number: INSTALLER: PLEASE LEAVE THIS MANUAL WITH THE CUSTOMER CUSTOMER: PLEASE KEEP MANUAL FOR FUTURE REFERENCE WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result casing property damage, personal injury may result.
  • Page 2: Table Of Contents

    Notes / Service History ............................35 Your Blaze King Stove has its own personal serial number. No two stoves are alike. The serial number is located on the stove label inside the door on the left hand side of the stove.
  • Page 3: Listing And Codes

    Introduction Thank you for purchasing a Blaze King stove and welcome to the Blaze King family. Your new Blaze King will give you many hours of warmth and comfort. Please make sure you take a few minutes to read this owner’s manual.
  • Page 4: Copy Of Certification Label

    In the event of a discrepancy between the labels, the label on the unit is considered as the correct one. OM6003.PUB Page 4 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 5: Lighting Instructions

    The Contemporary by Blaze King Owners Installation and Operation Manual Lighting Instructions OM6003.PUB Page 5 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 6: Specifications

    A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4. Contemporary - Stove Dimensions WIDTH 22” / 559mm HEIGHT 29.5” / 749mm DEPTH 18” / 457mm OM6003.PUB Page 6 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 7: Warnings, Caution And Safety Notices

    SAME ROOM AS THE APPLIANCE . They should be installed by a qualified gas installer for safety purposes. OM6003.PUB Page 7 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 8: Installation Instructions Safety

    Also ensure that proper grounding is provided by using a #8 grounding lug, wire and a star washer. OM6003.PUB Page 8 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 9: Clearances To Combustibles

    Cut 10” square hole. Measure from floor finish to center—24” Follow venting manufacturer ‘s instructions and adhere to all local codes, authorities and standards for your installation. OM6003.PUB Page 9 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 10: Simpson Duravent Parts List

    Flashing 0/12-6/12 46DVA-F6 Flashing 7/12-12/12 46DVA-F12 943S Storm Collar 46DVA-SC Vinyl Siding Standoff 46DVA-VSS Wall Strap 46DVA-WS Wall Pen Heat Shield (Wall Thimble) 46DVA-WT OM6003.PUB Page 10 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 11: American Metal & Security Parts List

    Wall Band SV4BM Insulated Attic Shield SV4RSA Wall Shield SV4RSM Firestop SV4BF Adjustable Roof Flashing 1/12 — 7/12 SV4FA Horizontal Termination SV4CHC Vertical Termination SV4CGV OM6003.PUB Page 11 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 12: Selkirk Direct-Temp™ Instructions

    Owners Installation and Operation Manual SELKIRK DIRECT-TEMP™ INSTRUCTIONS INSTALLATION INSTRUCTION APPENDIX FOR BLAZE KING MODEL: 6003-****-NT Selkirk Model Direct-Temp™ direct venting system has now been added as an approved venting option by our safety certification organization, Intertek Testing Services / Warnock Hersey (ITS/WH), for the above referenced direct vent gas appliances.
  • Page 13: Top Vent - Venting Diagrams

    MAXIMUM HORIZONTAL from the top of the stove). Restrictor Sizes vertical height in feet (ft) none NO INSTALLATION NO INSTALLATION horizontal length in feet (ft) OM6003.PUB Page 13 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 14 “ghosting”. Carefully monitor the flame and ensure the air adjustment is correct to provide the desired flame and proper burning efficiency. Picture #2 Picture #1 :\pubdata\manual\Ventrestrictor_IN.pub OM6003.PUB Page 14 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 15: Horizontal Termination Installation

    Ensure that the straps are hidden by the wall thimble cover. Apply Apply sealant decorative trim if required. On four sides OM6003.PUB Page 15 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 16: Vent Restrictor Use And Installation

    Proper instructions for installing a vent restrictor are included in the vent restrictor kit. 4” Collar attached OM6003.PUB Page 16 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 17: Through Roof Termination

    Note: Do not fasten down until the final adjustments to the vent have been made. OM6003.PUB Page 17 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 18: Elbow Offset Information

    Offset Offset chart for 45° Elbows Twist lock Joints Offset Pipe Length Height Wall thimble or inches inches inches fire-stop 1219 1194 OM6003.PUB Page 18 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 19: Termination Location

    A minimum clearance value determined by testing in accordance with section 2.23.7, or ; b) A reference to the following footnote: “Clearance in accordance with local installation codes and the requirements of the gas supplier” OM6003.PUB Page 19 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 20: Gas Supply

    Maximum gas supply pressure should never exceed 14.0 in. w.c. (3.48 kPa) or 1/2 psi. for both natural gas and propane. BE SURE TO TIGHTEN THE PRESSURE TAP SET-SCREW AFTER CHECKING THE PRESSURE. CHECK ALL GAS CONNECTIONS FOR GAS LEAKS. OM6003.PUB Page 20 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 21: Aeration Adjustment

    Recommended 12.5”w.c IMPORTANT: Always check for gas leaks with soap and water solution or gas leak detector. Do not use open flame for leak detection. OM6003.PUB Page 21 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 22: Thermostat

    If logs are broken, do not operate the unit until they are If required, a wall thermostat may be installed. Blaze King replaced. provides a thermostat but any CSA, ULC or UL approved 250...
  • Page 23: Wiring Diagrams

    Thermostat On/Off Rocker Switch #0725 Thermocouple Thermopile Thermostat leads or leads to optional remote thermostat Pilot Gas Line TP-TH THTP SIT Gas Valve #SIT0820652 OM6003.PUB Page 23 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 24: Operating Instructions Pre Check

    WARNING Do not operate appliance with the viewing glass removed, cracked or broken. Viewing glass must be replaced / repaired by BLAZE KING. For replacement please contact your local dealer or Blaze King to make arrangements to have your viewing glass replaced / repaired. Glass breakage due to slamming the viewing door or abusing your unit, is not covered under warranty.
  • Page 25: Final Check

    COMPLETE SHUT-DOWN  Press and turn the knob clockwise to the OFF position. CONTROL KNOB POSITIONS Unit Off Burner On Pilot Robertshaw Robertshaw Robertshaw OM6003.PUB Page 25 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 26: Fan

    POLISH PLUS by KEL KEM c) COOK TOP CLEAN CREME by ELCO d) WHITE OFF by RUTLAND NOTE: This is a problem beyond Blaze King’s control and is not covered under warranty. NOTICE: COLD WEATHER OPERATION When using any gas appliance (LPG or NAT Gas) water is a byproduct of the combustion process. Under normal conditions this moisture is expelled through the vent into the atmosphere and does not cause any harm.
  • Page 27: Maintenance Gas Valve Replacement

    1. Use a 1/2” wrench to loosen and remove the burner and remove the valve. orifice. Replacing the assembly is the reverse of the above Change the orifice. instructions. OM6003.PUB Page 27 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 28: Viewing Glass Replacement

    This appliance is supplied with high temperature 5mm high temperature ceramic glass that will easily withstand the heat your unit was designed to produce. In the event the glass breaks, contact your dealer or BLAZE KING to arrange for your glass to be replaced / repaired. (see page 22) REMOVING THE BLOWER: 1.
  • Page 29: High Altitude Chart

    In the absence of local codes in accordance with CSA B149.1, in Canada. In the US for installations above 2000ft the appliance must be installed in accordance with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54. OM6003.PUB Page 29 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 30: Optional Conversion Kits

    If you have changed from Propane to Natural gas you may have to REDUCE the aeration opening as Natural gas re- quires less primary air to burn correctly. OM6003.PUB Page 30 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 31: Warranty

    If this product requires repair or replacement due to defects in material or craftsmanship during the first five years of ownership, contact your Blaze King dealer and explain the nature of the problem. If the dealer is unable to repair or replace the product to your satisfaction then contact Blaze King at 509-522-2730 in the USA or 250- 493-7444 in Canada.
  • Page 32: Troubleshooting

    With the speed control by-passed check for 120 VAC to the motor. If you have 120VAC  and the motor is not working, the blower motor is defective. OM6003.PUB Page 32 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 33: Replacement Parts List

    THIS CAN CAUSE STRIP BY IMPROPER PLACE- DISTORTION OF THE MENT OF END WRENCH. ORIFICE STRIP 4) INSTALLATION IS WHEN LOOSENING COMPLETE. OR TIGHTENING. OM6003.PUB Page 33 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...
  • Page 34: Pilot Conversion

    The Contemporary by Blaze King Owners Installation and Operation Manual NOTES SERVICE HISTORY DATE CORRECTIVE ACTION (INCLUDE REPLACEMENT PARTS) OM6003.PUB Page 34 DATE PRINTED: 4/7/11 © Blaze King Industries Canada Ltd June 2006 Version 1.07SIT...

Table of Contents