2. To remove the Electronic Controllers:
• Release the 2 Particular Piece. (Fig. 3)
• Release the earth wire screw. (Fig. 3)
• Release the screw holder terminal board. (Fig. 3)
• Release the CN-DISP connector. (Fig. 3)
• Release the CN-TH connector. (Fig. 4)
• Release the CN-ION connector. (Fig. 4)
• Release the CN-SONIC connector. (Fig. 4)
• Release the CN-STM1 connector. (Fig. 4)
• Release the CN-STM2 connector. (Fig. 4)
• Release the hooks that hold the Electronic Controller
and pull out the Electronic Controller. (Fig. 4)
• Release the CN-FM connector. (Fig. 4)
• Release the AC01 (white) connector. (Fig. 4)
• Release the two RY-PWR connector. (Fig. 4)

12.3. Cross Flow Fan and Indoor Fan Motor Removal Procedures

1. In order to remove the Cross Flow Fan and Indoor Fan
Motor, Control Board need to be taken out by releasing all
the connectors as indicated below.
a. Release the Earth Wire screw. (Fig. 5)
b. Release the CN-TH connector. (Fig. 5)
c. Release the CN-ION connector. (Fig. 5)
d. Release the CN-SONIC connector. (Fig. 5)
e. Release the CN-STM1 connector. (Fig. 5)
f. Release the CN-STM2 connector. (Fig. 5)
g. Release the CN-DISP connector. (Fig. 5)
h. Pull out the Drain Hose from outlet to remove the
Discharge Grille. (Fig. 5)
2. Release the ION connectors. (Fig. 6)
3. Release the 3 screws. (Fig. 6)
4. By pressing down the hook at the left, you will be able to
remove the Control Board. (Fig. 6)