Wiring the FH8000F (Furnace) Honeywell Enhanced Air Cleaner

STEP ONE: Wiring the FH8000F (Furnace)
a. Ensure power has been removed from the heating and cooling system.
b. Turn the Honeywell Enhanced Air Cleaner power switch off.
c. Connect the power cord to the power supply connector (see Fig. 15).
d. Secure the power cord ground wire to the ground terminal on the cabinet using the screw provided in the
ground terminal (see Fig 15).
POWER CORD
TO EAC
TERMINALS
e. Route the power cord through nearest cabinet hole and protect with enclosed cable connector. Zip ties have
been enclosed to secure the power cord to the side of the power supply.
TrueCLEAN™ Enhanced Air Cleaner 68-0308EFS—03
USE CABLE CONNECTOR
TO SECURE POWER
CORD TO CABINET
CONNECTOR
POWER SUPPLY
CONNECTOR
POWER SUPPLY
USE WIRE TIES TO SECURE
POWER CORD TO
POWER SUPPLY ENCLOSURE
ALTERNATE POWER CORD
PASS-THRU HOLE
DETAIL A
Fig. 15. Electrical connections.
POWER CORD
POWER
SUPPLY
GROUND WIRE
FROM POWER CORD
SAMPLE FURNACE CIRCUIT BOARD
LHT
OFF
DLY
TEST/TWIN
HUM
0.5-AMP024 V AC
FUSE 3-AMP
SEC-1
SEC-2
EAC-2
NEUTRAL-L2
BLW
B
/ I H
O L
R
BHT/CLR
EAC-2 TERMINAL
COOL
1-AMP@115 V AC
SPARE-1
SPARE-2
EAC-1
EAC-1 TERMINAL
GROUND WIRE
TO BE SECURED
TO CABINET
(SEE DETAIL A)
USE TERMINALS TO
CONNECT THE
POWER CORD
WIRES TO THE
FURNACE
EAC-1, EAC2, AND
GROUND TERMINALS.
L B
W
R
PR-1
HSI
HI LO
M31366
17