Honeywell TrueCLEAN Professional Installation Manual page 6

Enhanced air cleaner
Table of Contents

Advertisement

Available languages

Available languages

Application Considerations
Electrical Power / Airflow Switch
The Honeywell Enhanced Air Cleaner should only be powered when airflow is present.
FH8000A
– These models are designed for use with an air handler and are equipped with an airflow switch (see
Fig. 1), which provides power only when the air handler blower is operating. These models are designed to be
powered from a 208 to 230 VAC single phase power source.
M28899
Fig. 1. Airflow Switch.
FH8000F
– The furnace control EAC terminals provide power to the unit only when the furnace blower is
operating. These models are designed to be powered from the electronic air cleaner (EAC) terminals on a furnace
control board. If EAC terminals are not available, an alternative airflow sensing mechanism such as the Honeywell
50027910-001 Differential Pressure Switch must be used to ensure the Honeywell Enhanced Air Cleaner is only
powered when airflow is present. Contact your local Honeywell distributor for information on alternatives.
TrueCLEAN™ Enhanced Air Cleaner 68-0308EFS—03
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents