Dimplex EF3003 Parts & Service Manual page 18

30" fireplaces
Hide thumbs Also See for EF3003:
Table of Contents

Advertisement

EF3003, SF3003, DF3003
If unit was operating prior to servicing allow at least 10 minutes for light bulbs and
heating element to cool off to avoid accidental burning of skin.
Disconnect power before attempting any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
TO REPLACE FLAME MOTOR/FLAME ROD
14. Pick up wire connector and place (1) yellow wire into each terminal. (total of 2
yellow wires)
15. Secure wire connector by crimping the 3M symbol with slip joint pliers.
16. Pull on end of wires to ensure a strong connection.
17. Repeat this process for the (4) remaining wires. (red, blue, orange, grey)
18. Reassemble in the reverse order.
16