Page
3. C Page Table
Address
Initial value
NTSC PAL
AB
AC
5-35
AD
AE
AF
3-5-2. BIST Check
1-4. IC1600(SFD) BIST(PB) Check
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: C, address: AC, set data: 21, and press the PAUSE
button.
3)
Select page: C, address: AD, and note down the data.
When the data is "00", change it to "01" and press the PAUSE
button.
5-49
When the data is "02", change it to "03" and press the PAUSE
button.
4)
Select page: 3, address: 11, set data: 04, and press the PAUSE
button.
12) Select page: C, address: AC, set data: 20, and press the PAUSE
button.
13) Select page: C, address: AD, set the data noted down at step 3),
and press the PAUSE button.
14) Select page: 0, address: 01, and set data: 00.
2-3. IC1600(SFD) BIST(REC) Check
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: C, address: AC, set data: 21, and press the PAUSE
button.
3)
Select page: C, address: AD, and note down the data.
When the data is "00", change it to "01" and press the PAUSE
button.
When the data is "02", change it to "03" and press the PAUSE
5-51
button.
4)
Select page: 3, address: 11, set data: 04, and press the PAUSE
button.
11) Select page: C, address: AC, set data: 20, and press the PAUSE
button.
12) Select page: C, address: AD, set the data noted down at step 3),
and press the PAUSE button.
13) Select page: 0, address: 01, and set data: 00.
New
Remark
Fixed data-1
Fixed data-2
Data
IC1602 of VI-151 board
00
CXD3200R-T6
02
SN104266PN-TEB
Fixed data-1
(Initialized data)
— 18 —