Dehumidifying area I: Operation at the frequency in the range (30 – 80 Hz) according
to ∆t (T
-T
indoor ambient
set
∆t(¡æ )
0
0.5
1
1.5
¡Ý 2
Efficient
Dehumidifying area II: The compressor stops for 5 minutes and operates for 5 minutes
at the lowest frequency.
Dehumidifying area III: The compressor stops.
4.5 Air Blowing mode
The outdoor unit does not work while the indoor fan runs with the fan speed selectable
at the auto, low, medium and high speeds.
When being auto, the fan speed is determined in the cooling mode (with the
temperature setting of 24
The high, medium and low fan speeds are same with that in the cooling mode.
5. Compressor operating state indication
When the compressor is in operation, The 3 LED indicator lights on the control panel
of the outdoor unit indicates the causes of the restriction on the compressor' s current
operating frequency.
Symbols for indicator light:: ¡ï : ON
LED1
LED2
Ο
Ο
1
D
E
L
D
E
L
II
).
f(Hz)
30
30
40
50
60
80
0
C in default).
Ο: flashing
The cause of the restriction on the compressor' s
LED3
current operating frequency
Ο
Normal frequency ascent and descent with no
restriction on the frequency
A
D
M
-
2
A
D
M
-
2
III
Time
×: OFF