preset speed. When the fan speed setting is automatic, the fan speed is set based on
the difference in room temperatures.
T
T
T
room ¡Ü
set
0
2
C ¡Ü T
T
room
4.2.4 Prevention against condensation and insufficient heat exchange at the low
indoor fan speed.
When the indoor fan speed is set at the low fan speed, the compressor' s power is
restricted as in the low temperature cooling.
4.2.5 4-way valve
State: It is interrupted in cooling.
4.2.6 Anti-freeze protection
4.2.6.1 Condition for anti-freeze interruption: When the indoor heat exchanger
temperature is below the Anti-freeze Interruption Temperature £ ¨ 0¡æ £© and maintains for
10 s, the system is interrupted for the anti-freeze.
Action of anti-freeze interruption: The compressor is interrupted, the outdoor fan stops
and the indoor fan remains running.
Condition for anti-freeze left: When the indoor heat exchanger temperature rises to
the Anti-freeze Releasing Temperature(9¡æ ), the anti-freeze interruption is left.
4.2.7 Compressor discharge temperature too high protection
4.2.7.1 Conditions for the compressor discharge interruption protection: The
compressor discharge temperature is above or equal to 115
the compressor discharge interruption protection is activated.
Action of the compressor discharge interruption protection: Prompts are made on the
remote controller display screen and with the outdoor indicator light and the
compressor stops.
Conditions for the compressor discharge interruption protection left: When the
compressor discharge temperature drops below 92
interruption protection is left.
4.2.8 Overcurrent protection in cooling:
4.2.8.1 Conditions for overcurrent protection: When the current rises above or at the
Interruption Current Value for the Cooling Current Protection(23A£© and maintains for
10 s, the overcurrent protection is activated.
Action of the overcurrent protection: Prompts are shown on the screen on the remote
controller unit and by the indicator light on the outdoor unit. The compressor stops.
Conditions for overcurrent protection left: When the current drops below the Value of
the Current for the Cooling Current Protection Left(13A£© , the overcurrent protection is
left.
4.3 Heating-run mode
4.3.1 Temperature compensation
Principle for compensation: The compensation is available only if the proper sensor is
used and it is not available when it is subject to the sensor on the remote controller or
D
E
L
D
E
L
-T
room
set
<2
0
OR T
-T
C
room
set
<4
0
-T
C
room
set
0
-T
4
C
set ¡Ý
A
D
M
-
2
A
D
M
-
2
Indoor fan speed
Low
Medium
High
0
C£¬ and remains for 20 s£¬
0
C, the compressor discharge
19
4
U
X
4
S
G
K
A
4
U
X
4
S
G
K
A