The table below gives the recommended drive parameter settings.
Drive parameter
50.01 FBA A enable
50.02 FBA A comm loss
func
50.03 FBA A comm loss t
out
50.04 FBA A ref1 type
51.01 FBA A type
51.02 Protocol/Profile
51.03 Commrate
51.04 IP configuration
51.05 IP address 1
51.06 IP address 2
51.07 IP address 3
51.08 IP address 4
51.09 Subnet CIDR
51.23 ODVA speed scale
52.01 FBA data in1
52.03 FBA data in3
53.01 FBA data out1
53.03 FBA data out3
Setting for ACS880
/ACS580 drives
2)
1 = Option slot 1
2)
1 = Fault
2)
3.0 s
4 = Speed
1)
128 = ETHERNET
100 = EIP AC/DC
2)
0 = Auto
2)
0 = Static IP
2)
192
2)
168
2)
0
2)
16
2)
24
2)
128
2)
01.14
2)
01.11
2)
22.26
2)
22.27
EtherNet/IP – Start-up 147
Description
Enables communication between
the drive and the fieldbus adapter
module.
Enables fieldbus A
communication fault monitoring.
Defines the fieldbus A
communication break supervision
time.
Selects the fieldbus A reference 1
type and scaling.
Displays the type of the fieldbus
adapter module.
Selects the EtherNet/IP protocol
and the ODVA AC/DC drive
profile.
Ethernet communication rate is
negotiated automatically by the
device.
Configuration will be obtained
from configuration parameters
05...13.
First part of the IP address
Second part of the IP address
Third part of the IP address
Last part of the IP address
Sets the network mask as
255.255.255.0, allowing access
only to the last subnet.
Sets the scaling for the ODVA
speed reference.
Output power
DC voltage
Constant speed 1
Constant speed 2