Specifications (cont'd)
Hydraulic Power Source
Do not exceed the following hydraulic power source
maximums:
• Hydraulic flow: 22.7 l/min (6 gpm)
• Pressure relief: 138 bar (2000 psi)
• Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe
injury or death.
Type of Hydraulic System ........................ Open-center or
Flow
Minimum .........................................15.1 l/min (4 gpm)
Recommended ...............................18.9 l/min (5 gpm)
Maximum ........................................22.7 l/min (6 gpm)
Filtration ............................................ 10 micron (nominal)
Operating Pressure
Minimum ......................................... 121 bar (1750 psi)
Maximum ........................................ 138 bar (2000 psi)
Pressure Relief Setting ........................ 138 bar (2000 psi)
Back Pressure (maximum)* .................. 13.8 bar (200 psi)
* 13.8 bar (200 psi) is the maximum agreed stan-
dard back pressure for the HTMA (Hydraulic Tool
Manufacturers Association). Greenlee Utility tools will
operate satisfactorily at this standard.
1. Maximum hydraulic fluid temperature must not
exceed 60 °C (140 °F). A sufficient oil cooling
capacity is needed to limit the hydraulic fluid
temperature.
2. Hydraulic flow must not exceed 22.7 l/min (6 gpm).
Install a flow meter in the return line to measure the
rate of hydraulic flow before using the tool.
3. Pressure relief valve setting must not exceed
138 bar (2000 psi) at the tool's maximum flow.
Locate the pressure relief valve in the supply circuit
to limit excessive hydraulic pressure to the tool.
Greenlee / A Textron Company
43180 Overhead Circular Saw
Hydraulic Schematic
RESERVOIR
Recommended Hydraulic Fluids
closed-center
Use any non-detergent, petroleum-based hydraulic
fluid which meets the following specifications or HTMA

specifications.

S.U.S. @
38 °C (100 °F) .............................................140 to 225
99 °C (210 °F) .......................................... 40 minimum
Flash Point ................................170 °C (340 °F) minimum
Pour Point ................................. –34 °C (–30 °F) minimum
8
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
FILTER
(10 micron)
RELIEF
COOLER
VALVE
138 bar
(2000 psi)
CONTROL
VALVE
FLOW METER
PUMP
POWER SOURCE
Electric shock hazard:
When using this tool near ener-
gized electrical lines, select and
maintain the hydraulic fluid to meet
the minimum dielectric standards
required by your safety department.
Failure to observe this warning could
result in severe injury or death.