Pressing key 1 will display Normally Open
Pressing key 2 will display Normally Closed
Pressing key 3 will display Change of State
After making your selection, press ENTER to store.
Display will change to:
This indicates the time that the contacts must remain in the active state to effect a trigger. A value of
between 0 and 15 can be entered, which represents blocks of 0.25 seconds (approximately). Therefore, a
value of 14 would equate to 3.5 seconds.
After making your selection, press ENTER to store; display will change to:
For added safety, when in Normally Open Mode the message is repeated whilst the contact remains in the
closed state. This screen allows you to select the time gap between each repeat transmission. Each unit
represents a block of 10 seconds.
After making your selection, press ENTER to store; display will change to:
Type in the pager no. which you wish to activate when contact 1 is triggered.
After making your selection, press ENTER to store; display will change to:
Select a number between 1 - 4 (represents bleep types A,B,C,D) to set the bleep type.
After making your selection, press ENTER to store; display will change to:
Type in the numeric message you wish to appear on the pager. Press ENTER to store. Screen will then run
through the same sequence for contact no. 2 (if selected). When complete, screen will revert to the main
programming menu.
DPMK2/6
TRIG. TIME 0-15:
>
REPT. TIME 0-15:
>
INPUT 1 PAGER
>
INPUT 1 TONE:
>
INPUT 1 MESSAGE:
>