Liability Scope does not accept liability for any damage or injury, howsoever caused as the result of misuse of this equipment. It is the responsibility of the user to ensure that the equipment is operated in the manner for which it was intended and that it is the correct item of equipment for the required task.
ConneXions II V8 (Euro), Multi Port Version System Overview The Scope ConneXions II V8 (Euro) is a POCSAG data display radio paging system which can be used to transmit both text and numeric messages direct to pocket pagers carried by individuals or entire groups.
Page 5
Warning! Never transmit without an aerial attached to the transmitter Warning! Carefully check the Installation section in this manual covering data pin connections prior to installation. Damage caused by incorrect connection is the responsibility of the installer! CONX8E/3 Issue 3...
(DTR) OUT GROUND (GND) REQUEST TO SEND (RTS) OUT CLEAR TO SEND (CTS) IN +5V 100mA max (PL2 only) (for Scope peripherals) PL1 SERIAL PORT (25 way D type plug) SIGNAL DIRECTION TRANSMIT DATA (TX) OUT RECEIVE DATA (RX) IN...
Page 7
LED on the base of the unit will light momentarily. Radio Transmission Baud Rate This is fixed at the factory to suit the pagers supplied and will normally be set at either 512 or 1200 baud CONX8E/3 Issue 3...
Page 8
ConneXions II V8 (Euro), Multi Port Version CONX8E/3 Issue 3...
20 numeric digits. As a default, contacts are programmed as Normally Open (N/O), with a repeat transmission every two minutes if still active. Note: repeats are not available where contacts are programmed as Normally Closed (N/C). CONX8E/3 Issue 3...
In the event that a pager requires service, return it directly to Scope in the pre-addressed service bag supplied with your system by registered post. Ensure that you carefully fill out the service form provided.
PL1, PL2: 1200 Baud. PL3: 9600 Baud* Footprint (mm): 328 (L) x 190 (W) x 75 (D) max *dependent on system configuration excluding aerial Scope’s policy is one of continuous development and specifications are subject to change without notice CONX8E/3 Issue 3...
Numeric Pagers Example serial message string:- N0012300A1234567890<CR> The ‘N’ informs the transcoder that this message is destined for a Numeric pager. Any data not preceded by this will be ignored. CONX8E/3 Issue 3...
Page 13
To change the transmission baud rate in a message string, placing a letter “N” after the “A” will alter it to 512 baud. Placing a letter “F” after the “A” will alter it to 1200 baud. The default setting for the Connexions II V8 (Euro) is 1200 baud. ************************************************************************ CONX8E/3 Issue 3...