Viper 5601 Installation Manual page 49

Security and remote start
Hide thumbs Also See for 5601:
Table of Contents

Advertisement

When set to voltage (2), the unit cranks the starter for the programmed time and
then attempts to sense that the engine is running by detecting an increase in volt-
age. If programmed OFF (3) the vehicle cranks for the programmed crank time
(feature 3-3) and does not verify with tach or voltage that the car is running. In
the OFF setting, if the vehicle fails to start, the ignition can stay on for the entire
run duration. When set to Tachometer (4), the unit references the learned tach
signal to disengage the starter. In addition it monitors the RPM and shut down if
the engine RPM is too high or too low.
Note:
The tach wire must be connected and programmed for the manual trans-
mission mode to work.
3-3 Crank Time 0.6 (1)
4.0 (9) SECONDS: If the unit is programmed for no engine checking or voltage
sense, the crank time must be set to the appropriate duration. The default setting
is 0.6 second and the LED flashes once. If a different crank time is desired,
toggle through the higher settings by using the two-chirp settings.
Note:
The numbers in parentheses indicate the number of times the LED flashes.
3-4 Run Time 12 (1)
that the system operates the engine until the system "times out". The system may
be shut down using the remote or any of the shutdowns at any time. Using
the Bitwriter®, the run time can be programmed for any duration from 1-60
minutes.
3-5 Activation Pulse One:
the remote start sequence. The default setting is 1-pulse.
Note: This setting affects both the input wire and the remote control.
3-6 Turbo Mode:
OFF
5 (4) and 10 MINUTES (5): There are two ways that "turbo timer mode" can
be activated, one by remote and the other manually.
AUX
To activate Turbo mode by remote the vehicle needs to be running. Press the
button on the remote two times and then press the
receive a confirmation tone on the remote you can turn Off the ignition and the
car remains running for the pre-programmed amount of time.
To activate manually, a push button needs to be hardwired to the (-) activation
© 2008 Directed Electronics. All rights reserved.
0.8 (2) 1.0 (3) 1.2 (4) 1.4 (5) 1.6 (6) 1.8 (7) 2.0 (8)
, 24 (2) 60 (3) MINUTES:
This allows the system to use 1 or 2 pulses to activate
The factory default is OFF (1). ON - 1 min. (2), 3 (3)
Selects the time in minutes
button. When you
AUX
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents