Power Dissipation - Philips CDD260 User Manual

Table of Contents

Advertisement

Dimensions
Height
Width
Depth
Weight max.

Power dissipation

Environmental
Operating temp
Non operating temp
Reliability
MTBF (hours)
Media
Certification
(1) Specifications for the "under pressure" case (incomming air flow through the
front bezel) : A flow of at least 2 l/sec. of air at maximum 40°, must be realised.
This will be achieved by realising at least -180 Pascal of pressure difference
between inside the apparatus and outside.
Specifications for the "over pressure" case (outgoing air flow through the front
bezel) : A flow of at least 2 l/sec. of air at maximum 40°, must be realised. This will
be achieved by realising at least +180 Pascal of pressure difference between inside
the apparatus and outside. Additionally, the measured temperature of the bottom
plate of the drive must not exceed 50° C.
Remark: under an environmental temperature of the drive between 5° to 30° C no
airflow is necessary.
ADDITIONAL INFORMATION
(1)
41.5 mm
146 mm
206 mm
1 kg
max. 8W
5 to 40 ° C
-25 to 70 ° C
30.000 POH
CD-R conf. "Orange Book"
part II
FCC Compliance: Class B.
UL, CSA,CEBEC.
FDA-CDRH.