VISIBLE EFFECTS
- At total selftest start:
INDIVIDUAL TESTS
You can reach Philips the following ways (in order of prefer-
Green, orange and red will respectively light up for
about 200 msec. this will be repeated 3 times.
- At start of each individual test:
The two LEDS will go on for 0.5 sec. and then the
test starts.
- During the test:
The two LEDS remain on.
- At the end of an individual test: if the test was
unsuccessful, the red error led will go on for 1 sec. If
the test was successful, the green led will go on.
- At the end of the selftest:
During 5 seconds, the orange and the green led will
flash if the whole test was OK. In case of an error,
the orange and the red light will flash during
.
5 seconds
- Test internal processor RAM
- Test external SRAM
- Test EPROM
- Test DSP interface
- Test DRAM
- Test SCSI interface
- Test CDB2 interface
- Test datapath
- Test SRAM CDB2