Advertisement

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 40 C.F. R. PART 60 AND THE OREGON DEPARTMENT OF ENVIRON-
MENTAL QUALITY (D.E.Q.) PARTICULATE EMISSION STANDARDS BY E.E.M.C THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING
SERVICES TO STANDARDS: ULC S628, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
EPI 1101 & 1402
WOOD INSERT

SAFETY INFORMATION

WARNING
!
If the information in these instructions is not followed exactly, a
fi re or explosion may result causing property damage, personal
injury or death. Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage,
bodily injury or even death. Please read entire manual before
you install and use your appliance.
This appliance has not been tested with an unvented gas log
set. To reduce risk of fi re or injury, do not install an unvented
gas log set into the appliance.
- This appliance can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed too
close can catch fi re.
- Children and pets must be kept from touching the appliance when it is hot.
- The chimney must be sound and free of cracks. Before installing this unit,
contact the local building or fi re authority and follow their guidelines.
- Operate only with the door tightly closed.
- Burn wood behind the log retainer directly on the fi rebricks.
- Do not use an elevated grate or otherwise raise the fi re.
- At least 14 square inches of outside air must be admitted to the room or
directly to the unit through a 4" diameter pipe.
- This appliance is designed to burn natural wood only. Higher effi ciencies
and lower emissions generally result when burning air dried seasoned
hardwoods, as compared to softwoods or to green or freshly cut
hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline, engine oil,
etc.
- Do not burn treated wood, coal, charcoal, colored paper, cardboard,
solvents or garbage.
- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to
achieve heat output rates that exceed design specifi cations can result in
steel distortion and damage.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
1 4 0
2 I l
!
l u s
t r a t
e d
WARNING
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
1.27A
W415-0764 / B / 10.28.11
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon EPI 1101

  • Page 1: Safety Information

    Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com $10.00...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS 2.1.1 1101 DIMENSIONS (COMPLETE WITH FLASHING) 2.1.2 1402 DIMENSIONS (COMPLETE WITH FLASHING) SPECIFICATIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION INSTALLATION PLANNING MINIMUM CLEARANCE TO COMBUSTIBLES INSTALLATION 4.0.1 TYPICAL EXISTING MASONRY 4.0.2 FACTORY BUILT FIREPLACE LOW CLEARANCE FLUE CONNECTOR (1402) FINISHING BRICKS AND BAFFLES INSTALLATION...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Flashing, see “FLASHING INSTALLATION” section. 1 4 0 2 I l l u s t r a t Door, see “DOOR AND HANDLE INSTALLATION” section. Rating plate, see “RATING PLATE INFORMATION” Blower, see “BLOWER INSTALLATION” section. section. Brick and Baffles, see Draft, see “AIR CONTROL”...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS 2.1.1 1101 DIMENSIONS (COMPLETE WITH FLASHING) 44 ½” 28” 24” 31 ¼” 11” 21 ½” 20 ½” 20 ½” ” 2.1.2 1402 DIMENSIONS (COMPLETE WITH FLASHING) ” 44 ½” ” ” ” 5 ½” 31 ¼” 21 ½” 20 ¾” 19 ¾”...
  • Page 6: General Instructions

    Your appliance is the exact duplication of the clean-burning technology found in all Napoleon EPA certifi ed freestanding stoves and in particular that of the EPA 1100 and 1400. External modifi cations have been made to allow its installation as a “functional insert”...
  • Page 7 The 1101 insert must be installed into a solid fuel burning fi replace that is at least 16 1/2 inches deep, 28 1/2 inches wide and 22 inches high with an approved lined chimney at least 15 feet high (4.6m) and a hearth of 16”. Your 1402 insert must be installed only into a solid fuel burning fi...
  • Page 8: Rating Plate Information

    Certifié conforme à la norme d’ émanation de particles de juillet 1990: 40 CFR Part 60, Subpart AAA DATE CODE / DE DATE WOLF STEEL LTD. EPA1400 24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA W385-0401 / J 1400 SERIES RATING PLATE ILLUSTRATED W415-0764 / B / 10.28.11...
  • Page 9: Installation Planning

    3.0 INSTALLATION PLANNING Clean all ashes out of the inside of the existing fi replace opening. Make sure that the chimney and fi replace are free of cracks, loose mortar, creosote deposits, blockage or other signs of deterioration. If necessary, have any repair work done by a qualifi...
  • Page 10: Installation

    4.0 INSTALLATION WARNING WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION. CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS NEEDED TO INSTALL THE APPLIANCE. FAILURE TO DO SO MAY RESULT IN A FIRE, ESPECIALLY IF COMBUSTIBLES ARE TOO CLOSE TO THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE BLOCKED, PREVENTING THE FREE MOVEMENT OF COOLING AIR.
  • Page 11: Typical Existing Masonry

    4.0.1 TYPICAL EXISTING MASONRY WARNING DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. You can install your appliance using your existing masonry chimney. To do FOLLOW MANUFACTURER’S so, follow the guidelines below.
  • Page 12: Factory Built Fireplace

    4.0.2 FACTORY BUILT FIREPLACE The following installation requirements must be observed when installing solid fuel burning inserts into factory built fi replaces. The factory built fi replace must be listed per UL 127 or ULC S610. Clearances to any combustible material surrounding this insert as identifi ed must be followed. These clearance requirements supersede any pre-existing facing material clearances listed for the factory built fi...
  • Page 13: Finishing

    5.0 FINISHING BRICKS AND BAFFLES INSTALLATION WARNING OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERA- TURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING ENCLOSURE. Install (1101) four (A) bricks and one (C) brick or (1402) six (A) bricks along both sides of the appliance.
  • Page 14: Door Removal / Installation

    DOOR REMOVAL / INSTALLATION WARNING BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE. DO NOT STRIKE OR SLAM DOOR. NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT. Hang the door using the hinge pins supplied.
  • Page 15: Flashing Installation

    FLASHING INSTALLATION The top fl ashing has been shipped fl at. To install the fl ashing, rest the bottom against the top of the appliance and secure using the tabs as illustrated below. Slide the trim over the fl ashing. 1402 illustrated.
  • Page 16: Operation

    NEVER OPERATE THE STOVE WITH THE GRATE COVER REMOVED. Your Napoleon EPA listed product is designed with the most advanced technology. The appliance is extremely airtight. It has an exclusive direct outside air supply (optional kit), a safety feature designed to prevent spillage, and to keep your house free of carbon monoxide, in case of a down drafting chimney or an internal negative pressure.
  • Page 17: Blower

    You can now add larger pieces of wood and operate the appliance normally. Once the appliance is entirely hot, it will burn very effi ciently with little smoke from the chimney. There will be a bed of orange coals in the fi rebox and secondary fl...
  • Page 18: Air Control

    AIR CONTROL Draft is the force which moves air from the fi rebox up ASH LIP through the chimney. The amount of draft in your chimney depends on the length and diameter of chimney, local ge- ography, nearby obstructions and other factors including the amount of heat generated by the fi...
  • Page 19: Fuel

    FUEL THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY. DO NOT BURN TREATED WOOD, COAL, CHARCOAL, COLOURED PAPER, CARDBOARD, SOLVENTS OR GARBAGE. THIS APPLIANCE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THE APPLIANCE.
  • Page 20: Lighting A Fire

    LIGHTING A FIRE 6.5.1 FLASH FIRE A fl ash fi re is a small fi re burned quickly when you don't need much heat. After your kindling has "caught", load at least 3 pieces of wood, stacked loosely. Burn with the draft control fully open or closed only slightly.
  • Page 21: Maintenance

    7.0 MAINTENANCE WARNING TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for cleaning is established.
  • Page 22: Runaway Or Chimney Fire

    RUNAWAY OR CHIMNEY FIRE A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM. THIS DAMAGE CAN ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS. CHIMNEY FIRES ARE NOT COVERED BY THE LIFETIME LIMITED WARRANTY. CAUSES: • Using incorrect fuel, or small fuel pieces which would normally be used as kindling. •...
  • Page 23: Glass Replacement

    GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 24: Care Of Glass

    CARE OF GLASS If the glass is not kept clean permanent discolouration and / or WARNING blemishes may result. Normally a hot fi re will clean the glass. The most common reasons for dirty glass include: not using HOT GLASS WILL suffi...
  • Page 25: Blower Service Or Replacement (1101)

    BLOWER SERVICE OR REPLACEMENT (1101) Turn off all electrical power to the appliance. Remove the glass door and set GASKET aside in a safe place. Remove the top right side bricks from inside the fi rebox, 4-#7’s and 2-#2’s. Then remove the rest of the side and back bricks from the right side of the appliance.
  • Page 26 LEFT BLOWER ACCESS W415-0764 / B / 10.28.11...
  • Page 27: Replacements

    8.0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
  • Page 28 COMMON ACCESSORIES REF NO. PART NO. DESCRIPTION H222-G GOLD PLATED DOOR H222 BLACK DOOR H222-SS BRUSHED STAINLESS STEEL DOOR - STANDARD ARCH H222-W BLACK DOOR - EARLY AMERICAN H222-GW GOLD DOOR - EARLY AMERICAN H222-SSW BRUSHED STAINLESS STEEL DOOR - EARLY AMERICAN CISK** CAST IRON SURROUND KIT - PAINTED BLACK CISK**A...
  • Page 29: Troubleshooting

    9.0 TROUBLESHOOTING WARNING TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. WHEN CHECKING CONNECTIONS, INSTALLING JUMPER WIRES (FOR TEST PURPOSES ONLY) OR REPLACING COMPONENTS, UNPLUG HEATER FROM THE RECEPTACLE TO PREVENT ELECTRICAL SHOCK OR DAMAGE TO THE COMPONENT.
  • Page 30: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON®...
  • Page 31: Service History

    11.0 SERVICE HISTORY 43.1 W415-0764 / B / 10.28.11...
  • Page 32 12.0 NOTES 44.1 W415-0764 / B / 10.28.11...

This manual is also suitable for:

Epi 1402

Table of Contents