Napoleon 1100C Installation And Operation Instructions Manual

Napoleon 1100C Installation And Operation Instructions Manual

Hi-tech listed solid fuel burning stoves and inserts

Advertisement

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PAR-
TICULATE EMISSION STANDARDS BY E.E.M.C. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2 , ULC
S627, ULC S628, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
INSTALLATION AND OPERATION INSTRUCTIONS FOR
HI-TECH LISTED SOLID FUEL BURNING STOVES AND INSERTS
FREE STANDING MODELS
INSERT MODELS
Please read this entire manual before you install and use your new room heater. Failure to
follow instructions may result in property damage, bodily injury, or even death.
If this unit is not properly installed, a house fire may result.
Follow the installation directions. This unit can be very hot when burning. Combustible mate-
rials such as firewood, wet clothing, etc. placed too close can catch fire. Adults and especially
children should be alerted to the hazards of high surface temperatures and should stay away
to avoid burns or clothing ignition. Keep young children and animals away when the fireplace
is hot. The chimney must be sound and free of cracks. Before installing your unit, contact the
local building or fire authority and follow their guidelines.
The door must be kept closed during operation to prevent smoke, embers from entering the
room. Burn wood directly on firebricks. Do not use a grate or elevate the fire. At least 14 square
inches (90 sq.cm.) of outside air must be admitted to the room or directly to the unit through a
4 inch (10cm.) diameter pipe. This unit is designed to burn natural wood only. Higher efficiencies
and lower emissions generally result when burning air dried seasoned hardwoods, as com-
pared to softwoods or to green or freshly cut hardwoods. Do not start a fire with chemicals or
fluids such as gasoline, engine oil, etc. Do not burn treated wood, coal, charcoal, coloured
paper, cardboard, solvents or garbage which tend to produce more pollution than wood. Do
not let the unit become hot enough for any part to glow red.
KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to achieve heat output
rates that exceed design specifications can result in steel distortion and damage.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
EPA 1100, 1100L, 1100C, 1150, 1400, 1400L & 1900
EPI 1101, 1401
WARNING:
FOR YOUR SAFETY
www.napoleonfireplaces.com • ask@napoleon.on.ca
1
W415-0512 / B / 11.15.05

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon 1100C

  • Page 1 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www.napoleonfireplaces.com • ask@napoleon.on.ca EPA 1100, 1100L, 1100C, 1150, 1400, 1400L & 1900 EPI 1101, 1401 WARNING: FOR YOUR SAFETY W415-0512 / B / 11.15.05...
  • Page 2: Table Of Contents

    2-4 INTRODUCTION Warranty General Information Care of Plated & Enamelled Parts Care of Glass 5-6 INSTALLATION Installing the Legs Alcove Installation Stove Installation Chimney Connection Adding Chimney Sections Outside Air Wall Pass-through 6-7 MOBILE HOME Venting Outside Air 7-8 FIREPLACE INSERT...
  • Page 3 NAPOLEON products are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
  • Page 4: General Information

    If the glass should ever crack while the fire is burning, do not open the door until the fire is out and do not operate the stove again until the glass has been replaced with a new 5mm thick plate of ceramic glass, available from your Napoleon / Wolf Steel Ltd.
  • Page 5: Installation

    4. Use four of the nuts and washers removed above to install the legs as illustrated in FIGURES 2a & 2b. 5. Lift the stove up and gently set down on all four legs. Do not pivot unit up on its legs, as this could result in damage to the legs.
  • Page 6: Adding Chimney Sections

    Use only specified compo- nents with no substitutions. The chimney and pipe must extend at least 8 feet above the stove and 3 feet above the highest point of the roof. Install a rain cap at the top which will not impede the smoke exhaust.
  • Page 7: Outside Air

    OUTSIDE AIR Connection from the stove's air intake to the outside is man- datory in mobile homes only, either through a hole in the wall to line up with the knockout in the pedestal back, or through a hole in the floor to line up with the hole in the pedestal base.
  • Page 8: Installation Into A Factory Built Fireplace

    Use of the blower increases the output of heat. STOVE MODELS Provisions have been made on the stove to install an op- tional blower kit (EP62-1) that comes complete with a vari- able speed switch to turn the blower on and off, as well as adjusting the blower speed.
  • Page 9: 1401 Blower Service And Replacement

    LID LIFTER HOOK Remove the screw, as illustrated, from the preferred side of the stove rear. Secure the lid lifter hook, as illustrated, facing out to the side, or bend it towards the back. W415-0512 / B / 11.15.05...
  • Page 10: Finishing

    Fibre baffle - 9” x 1” x 16 1/2” #12. Fibre baffle - 9” x 1” x 9 3/4” #13. Fibre baffle - 9” x 1” x 9 3/4” MODEL 1100/1100C/1100L/1150 - FIGURE 21 MODEL 1400 / 1400L - FIGURE 23 MODEL 1900 - FIGURE 25 W415-0512 / B / 11.15.05...
  • Page 11: Ornamental Trivet Installation

    OPTIONAL ASH DRAWER KIT Models 1100L / 1400L Only: Provisions have been made on the stove to install an optional ash drawer kit. The EPAD- KT kit allows for convenient removal of excess ash. This kit can be purchased through your Napoleon Dealer.
  • Page 12: Achieving Proper Draft

    Without a stove thermometer, you are working blindly and have no idea of how the stove is operating! A stove thermometer offers a guide to performance. Can't get the fire going? Use more kindling and paper.
  • Page 13: Smoking

    If accumulation is excessive, disconnect the stove and clean both the chimney and the stove. You may want to call a professional chimney sweep to clean them. Both have to be cleaned at least once a year or as often as necessary.
  • Page 14: Door Removal

    Ideal lengths of wood are approximately 12" for EPA 1100, 1100C, 1100L, 1150 and 1101, 16 1/2" for EPA 1400, 1400L and 1401, and 21" for EPA 1900.
  • Page 15: Replacements

    VARIABLE SPEED CONTROL W KNOB # 11 FIBRE BAFFLE MANIFOLD GASKET & SHIELD COMPLETE BRICK SET 5/16" PLUG 1100C COMPONENTS BRICK - # 3 BRICK - # 5 BRICK - # 6 # 10 FIBRE BAFFLE MANIFOLD GASKET & SHIELD...
  • Page 16 PART NO. DESCRIPTION H222G GOLD PLATED DOOR H222 BLACK DOOR H222SS BRUSHED STAINLESS STEEL DOOR STANDARD ARCH H222W BLACK DOOR - H222GW GOLD DOOR - H222SSW BRUSHED STAINLESS STEEL DOOR EARLY AMERICAN W010-1071 DOOR GLASS W020-0043 DOOR GASKET W020-0050 GLASS GASKET CISK** CAST IRON SURROUND KIT, CISK...
  • Page 17 W415-0512 / B / 11.15.05...
  • Page 18 W415-0512 / B / 11.15.05...
  • Page 19 W415-0512 / B / 11.15.05...
  • Page 20 W415-0512 / B / 11.15.05...

Table of Contents