Napoleon EPA 1100 Installation And Operation Instructions Manual

Napoleon EPA 1100 Installation And Operation Instructions Manual

Hi-tech listed solid fuel burning stoves and inserts

Advertisement

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PAR-
TICULATE EMISSION STANDARDS BY E.E.M.C. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2 , ULC
S627, ULC S628, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
INSTALLATION AND OPERATION INSTRUCTIONS FOR
HI-TECH LISTED SOLID FUEL BURNING STOVES AND INSERTS
FREE STANDING MODELS
INSERT MODELS
Please read this entire manual before you install and use your new room heater. Failure to
follow instructions may result in property damage, bodily injury, or even death.
If this unit is not properly installed, a house fire may result.
Follow the installation directions. This unit can be very hot when burning. Combustible mate-
rials such as firewood, wet clothing, etc. placed too close can catch fire. Adults and especially
children should be alerted to the hazards of high surface temperatures and should stay away
to avoid burns or clothing ignition. Keep young children and animals away when the fireplace
is hot. The chimney must be sound and free of cracks. Before installing your unit, contact the
local building or fire authority and follow their guidelines.
The door must be kept closed during operation to prevent smoke, embers from entering the
room. Burn wood directly on firebricks. Do not use a grate or elevate the fire. At least 14 square
inches (90 sq.cm.) of outside air must be admitted to the room or directly to the unit through a
4 inch (10cm.) diameter pipe. This unit is designed to burn natural wood only. Higher efficiencies
and lower emissions generally result when burning air dried seasoned hardwoods, as com-
pared to softwoods or to green or freshly cut hardwoods. Do not start a fire with chemicals or
fluids such as gasoline, engine oil, etc. Do not burn treated wood, coal, charcoal, coloured
paper, cardboard, solvents or garbage which tend to produce more pollution than wood. Do
not let the unit become hot enough for any part to glow red.
KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to achieve heat output
rates that exceed design specifications can result in steel distortion and damage.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
EPA 1100, 1100L, 1100C, 1150, 1400, 1400L & 1900
EPI 1101, 1401, 1402
WARNING:
FOR YOUR SAFETY
www.napoleonfireplaces.com • ask@napoleon.on.ca
1
W415-0512 /C 10.02.06

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon EPA 1100

  • Page 1 INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PAR- TICULATE EMISSION STANDARDS BY E.E.M.C. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2 , ULC S627, ULC S628, UL 1482.
  • Page 2: Table Of Contents

    2-4 INTRODUCTION Warranty General Information Care of Plated & Enamelled Parts Care of Glass 5-6 INSTALLATION Installing the Legs Alcove Installation Stove Installation Chimney Connection Adding Chimney Sections Outside Air Wall Pass-through 6-7 MOBILE HOME Venting Outside Air 7-8 FIREPLACE INSERT Prior to Installation Installation into a Masonry Fireplace Installation into a Factory Built Fireplace...
  • Page 3 NAPOLEON products are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
  • Page 4: General Information

    GENERAL INFORMATION Except for their different depths, models 1100, 1150, 1400, 1900 and the fireplace inserts 1101, 1401, and 1402 are identical and use the same burning principles. They were specifically designed over many months of research to meet the 1990 U.S.A. EPA particulate emission standards and have been extensively tested in Canadian and American laboratories.
  • Page 5: Installation

    STOVE INSTALLATION INSTALLING THE LEGS To avoid being damaged during shipping, the stove has been bolted to the pallet and must be unbolted before the stove can be installed. 1. Remove the 4 nuts and washers from the underside of the pallet.
  • Page 6: Adding Chimney Sections

    THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE. All horizontal smoke pipe must slope slightly upwards a minimum of 1/4" per foot (6mm/ 0.3m) and all connections must be tight and secured by three sheet metal screws equally spaced.
  • Page 7: Outside Air

    FIGURE 11 It must be installed between ceiling joists, with radiation shield and roof flashing, so that the structural strength, insula- tion and waterproof qualities of the home are not lessened. Seal with silicone to maintain a vapour barrier at the chimney outside pipe penetrations.
  • Page 8: Installation Into A Factory Built Fireplace

    In the United States: While it is not required, it is rec- ommended that a chimney liner be installed that is con- tinuous from the insert to the top of the chimney, particu- larly when the insert is installed in a basement. For this type of connection, use the "In Canada"...
  • Page 9: 1401 Blower Service And Replacement

    3. The access panel can be removed by taking out the 8 #10 self taping screws. A 5/16" nut driver will be required to complete this job. Unplug wires from the thermal switch on the panel. See FIGURE 15. 4. Remove the securing wingnut from the blower mounting bracket, slide the bracket to the right and rotate the left side of the assembly out of the cavity to clear the blower motor.
  • Page 10: Finishing

    SIZES 1-1/4" x 4"-1/2 x 9" 1-1/4" x 3" x 9" 1-1/4" x 4-1/2" x 4-1/2" 1-1/4" x 4-1/2" x 9" 1-1/4" x 2-1/2" x 4-1/2" 1-1/4" x 1-1/2" x 4-1/2" 1-1/4" x 4-1/2" x 9" (light weight) 1-1/4" x 2-1/4" x 9" 1-1/4"...
  • Page 11: Ornamental Trivet Installation

    BRICKS AND BAFFLES INSTALLATION With stove and chimney installation completed, move the bricks into place by working as illustrated for your unit on page 10. 1. Install two or three courses of brick on both sides of the unit. Install two courses on the back wall. Install the final course of bricks on the back wall.
  • Page 12: Achieving Proper Draft

    You can now add larger pieces of wood and operate the stove normally. Once the stove/insert is entirely hot, it will burn very efficiently with little smoke from the chimney. There will be a bed of orange coals in the firebox and secondary flames flickering just below the top firebrick.
  • Page 13: Smoking

    SMOKING A properly installed Napoleon unit should not smoke. If yours does, check the following: Has the chimney had time to get hot? Is the smoke passage blocked anywhere in the stove, chimney connector or chimney? Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
  • Page 14: Door Removal

    DOOR REMOVAL (1100C ONLY) 1. Remove cast top. 2. Pull pin from top door hinge. It is important to hold the door while removing the pin. Pivot the door to clear the top door hinge. Lift the door off of the lower pin. Do not pivot the door any further than necessary.
  • Page 15: Replacements

    Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the follow- ing information: FOR WARRANTY REPLACEMENT PARTS ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM REPLACEMENT PARTS PART NO.
  • Page 16 PART NO. DESCRIPTION H222G GOLD PLATED DOOR H222 BLACK DOOR H222SS BRUSHED STAINLESS STEEL DOOR STANDARD ARCH H222W BLACK DOOR - H222GW GOLD DOOR - H222SSW BRUSHED STAINLESS STEEL DOOR EARLY AMERICAN W010-1071 DOOR GLASS W020-0043 DOOR GASKET W020-0050 GLASS GASKET CISK** CAST IRON SURROUND KIT, CISK...
  • Page 17 W415-0512 /C 10.02.06...
  • Page 18 W415-0512 / C 10.02.06...
  • Page 19 W415-0512 /C 10.02.06...
  • Page 20 W415-0512 / C 10.02.06...

Table of Contents