5. SPECIFICATIONS OF ELECTRICAL PARTS

5-1. Indoor Unit
RAS-M10YKV-E, RAS-M13YKV-E, RAS-M16YKV-E
RAS-M10YKCV-E, RAS-M13YKCV-E, RAS-M16YKCV-E
No.
Parts name
1
Fan motor (for indoor)
2
Thermo. sensor (TA-sensor)
3
DC-DC transformer (T01)
4
Microcomputer
Heat exchanger sensor
5
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C02)
9
Fuse (F01)
10
Power supply IC (IC01)
11
Varistor (R21, R109)
12
Resistor (R01)
13
Louver motor
Type
TICF-35-19-4
( – )
SWT-34
TMP87CM40AF
( – )
UF-253Y0R7
RBV-406 or D3SBA60
KMH450VNSN100M25B
TSCR6.3A
MA2830P-FJ
15G561K
ERF-5TK5R6
MP35EA7
– 38 –
Specifications
DC 35V, 19W
10kΩ at 25°C
DC 390V, Secondary DC 35V, 12V, 7V
10kΩ at 25°C
25mH, AC 0.7A
4A, 600V
100µF, 450V
T6.3A, 250V
8A, 850V
560V
5.6Ω, 5W
Output (Rated) 2W, 10 poles, 1 phase DC12V